Xylem FST Installation, Operation And Maintenance Manual page 23

Table of Contents

Advertisement

11.5" 1‐1/2" NTP resistive fuel level transducer
10.5" 1‐1/2" NTP resistive fuel level transducer
9.5" 1‐1/2" NTP resistive fuel level transducer
8.5" 1‐1/2" NTP resistive fuel level transducer
7.5" 1‐1/2" NTP resistive fuel level transducer
6.5" 1‐1/2" NTP resistive fuel level transducer
34" 1‐1/2" NTP resistive fuel level transducer
Connect the fuel level transducer to the control panel
1. Remove the existing fuel gauge from the fuel tank.
2. Apply the Teflon tape to the fuel level transducer.
3. Tighten the fuel level transducer into the 1.5" FNPT port.
4. Pass the red wire and the black wire through the cable gland on the bottom
of the control panel where the FST harness enters.
5. To open the control panel, remove the top two screws above the display
screen.
6. Connect the fuel level transducer to the control panel.
1. Fuel level transducer
2. Control panel
3. Red wire
4. Black wire
FST Installation, Operation, and Maintenance Manual
Fuel level transducer
2
1
3
4
4 Electrical Installation
Godwin part number
ACT‐10899
ACT‐10900
ACT‐10901
ACT‐10902
ACT‐10903
ACT‐10904
ACT‐10922
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents