Reference Manual
00809-0100-4928
C
High gain remote antenna option
C.1
Safety messages
Procedures and instructions in this section may require special precautions to ensure the
safety of the personnel performing the operation.
WARNING
•
When installing remote mount antennas for the wireless field device, always use
established safety procedures to avoid falling or contact with high-power electrical
lines.
•
Install remote antenna components for the transmitter in compliance with local and
national electrical codes and use best practices for lightning protection.
•
Before installing, consult with the local area electrical inspector, electrical officer, and
work area supervisor.
•
The wireless field device remote antenna option is specifically engineered to provide
installation flexibility while optimizing wireless performance and local spectrum
approvals. To maintain wireless performance and avoid non-compliance with spectrum
regulations, do not change the length of cable or the antenna type.
•
If the supplied remote mount antenna kit is not installed per these instructions,
Emerson is not responsible for wireless performance or non-compliance with spectrum
regulations.
•
Be aware of overhead electrical power lines.
C.2
Antenna functional specifications
C.2.1
Output
Wireless HART
Radio frequency power output from antenna:
•
High gain remote (WN option) antennal: maximum of 40 mW (16 dBm) EIRP
(equivalent isotropically radiated power)
C.2.2
Communications range
⅔ mile (3,300 ft.)(1.0 km) with L.O.S.
C.2.3
Coaxial length
25 ft. (7.6 m) with type N connections
®
2.4 GHz DSSS (direct sequence spread spectrum).
High gain remote antenna option
August 2018
185