Reference Manual
00809-0100-4928
Special conditions for safe use (X):
1. For use only with the Emerson
2. The surface resistivity of the antenna is greater than 1 Gigaohm. To avoid
3. Substitution of components may impair intrinsic safety.
B.6.3
Europe
I1
Refer to
Special conditions for safe use (X):
1. Under certain extreme circumstances, the non-metallic parts incorporated in the
2. The transmitter may contain more tha 10% aluminum and is considered a potential
3. The equipment shall be powered by Emerson
4. Only the 375, 475, or AMS Trex Communicators may be used with the 928.
B.6.4
International
I7
Refer to
Special conditions for safe use (X):
1. Under extreme circumstances, the non-metallic parts incorporated in the enclosure
MHM-89004, or the Perpetuum Ltd. IPM1008/IPM74001.
electrostatic discharge buildup, it must not be rubbed or cleaned with solvents or a
dry cloth.
ATEX Intrinsic Safety
Certificate: Sira17ATEX2371X
Standards: EN 60079-0:2012 + A11:2013, EN 60079-11:2012
Markings:
II1 G Ex ia IIC T4 Ga, T4 (-40 °C ≤ Ta ≤ +50 °C) IP66
Table B-1
and
Table
B-2.
enclosure of this equipment may generate an ignition capable of electrostatic
charge. Therefore, the equipment shall not be installed in a location where the
external conditions are conducive to the build-up of electrostatic charge on such
surfaces. In addition, the equipment shall only be cleaned with a damp cloth.
risk ignition by impact or friction. Care must be taken into account during
installation and use to prevent impact or friction.
source shall be the CSI MHM-89004 as this device has output parameters that are
equal or less onerous than the parameters of the 701PBKKF.
IECEx Intrinisic Safety
Certificate: IEcEX SIR 17.0091X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ia IIC T4 Ga, T4 (-40 °C ≤ Ta ≤ +50 °C) IP66
Table B-1
and
Table
B-2.
of this equipment may generate an ignition-capable level of electrostatic charge.
Therefore, the equipment shall not be installed in a location where the external
conditions are conducive to the build-up of electrostatic charge on such surfaces. In
addition, the equipment shall only be cleaned with a damp cloth.
Model 701PBKKF, the Computations Systems, Inc.
701PBKKF. An alternative power
Product certifications
August 2018
181