DO name display mode
In this menu, you can toggle the display of the DO-name between the standard abbreviation
(e.g., VECTOR) and a DO-name of your choice (e.g. motor_1).
User-defined DO name (factory setting: No)
● Yes: The "User-defined DO-name" stored in parameter p0199 is displayed instead of the
standard DO abbreviation.
● No: The standard DO abbreviation is displayed.
Scaling to motor current
In this menu, the reference variable for the bar-type display of parameter r0027 (absolute
actual current value smoothed) can be changed over in the operating screen forms.
Scaling to motor current (factory setting: No)
● Yes: The bar display of parameter r0027 in the operating screen form is displayed with
reference to parameter p0305 (rated motor current).
● No: The bar display of parameter r0027 in the operating screen form is displayed with
reference to parameter p2002 (reference current).
Reset AOP settings
When you choose this menu option, the AOP factory settings for the following are restored:
● Language
● Display (brightness, contrast)
● Operating screen
● Control settings
Note
Restoring the factory setting
When you reset parameters, all settings that are different to the factory settings are reset
immediately. This may cause the cabinet unit to switch to a different, unwanted operational
status.
For this reason, you should always take great care when resetting parameters.
Advanced Operator Panel 30 (AOP30)
Operating Instructions, 11/2017, A5E00331451A
Control via the operator panel
5.5 Menu commissioning / service