• Use extreme caution when entering or leaving the plat-
form. Ensure that the mast assembly is fully lowered. Face
the machine when entering or leaving the platform.
• Always maintain "three point contact" with the machine,
using two hands and one foot or two feet and one hand at
all times during entry and exit.

Electrocution Hazard

• This machine is not insulated and does not provide pro-
tection from contact or proximity to electrical current.
1-877-254-3876
1-877-2-LIFTPOD
• Maintain distance from electrical lines, apparatus, or any
energized (exposed or insulated) parts according to the
Minimum Approach Distance (MAD) as shown in
Table 1-1.
• Allow for machine movement and electrical line swaying.
Table 1-1. Minimum Approach Distances (M.A.D.)
VOLTAGE RANGE
(PHASE TO PHASE)
0-50KV
Over 50KV to 200KV
Over 200KV to 350KV
Over 350KV to 500KV
Over 500KV to 750KV
Over 750KV to 1000KV
NOTE: This requirement shall apply except where employer, local, or gov-
ernmental regulations are more stringent.
• Maintain a clearance of at least 10 ft. (3m) between any
part of the machine and its occupants, their tools, and
their equipment from any electrical line or apparatus car-
LIFTPOD by JLG
www.liftpod.com
SECTION 1 - SAFETY PRECAUTIONS
MINIMUM SAFE APPROACH
DISTANCE - Feet (Meters)
10 (3)
15 (5)
20 (6)
25 (8)
35 (11)
45 (14)