TROUBLE
Platform will not move when in elevated position - motor starts
Driveshaft interlock is engaged
(If using powerpack) Powerpack shaft not
engaged
Drive shaft malfunction
Ropes are loose (ropes must never be loose)
Machine was disassembled without platform
being fully lowered to engage the carriage lock
down latch. Carriage then moved up the mast
loosening the ropes
Machine does not wheel properly
Retractable Swivel Castor is not properly
deployed
Castor is damaged
1-877-254-3876
1-877-2-LIFTPOD
PROBABLE CAUSE
LIFTPOD by JLG
www.liftpod.com
Push cordless drill on driveshaft down firmly to disengage driveshaft safety inter-
lock.
Check powerpack charged and in correctly fitted and is fully down and latched
down.
Lower platform using manual descent procedure (see Section 4.1). Refer to
Authorized JLG Service Center.
If carriage is not within 1m (3 ft) of the base of the mast contact Authorized JLG
Service Center. Otherwise follow rope re-tensioning procedure detailed in Section
6.7, point 3. Ensure both ropes are tight and remain so at all times.
With no load in the platform or on the base - lift the castor deploy handle on front of
base, adjacent to platform gate. Castor should deploy and lift front of machine off
adjustable feet to allow machine to roll easily on rear wheels and front castor.
Replace castor.