Danfoss PVED-CLS Startup Manual page 28

Hide thumbs Also See for PVED-CLS:
Table of Contents

Advertisement

Application Guide
PVED-CLS startup guide
Parameter setting
Parameter
Conditions for value change
P3708-P3712
See
Parameter
Conditions for value change
P3698-P3718
See Section 11.6 Open Loop Anti-Jerk in the User Manual for configuration details.
Parameter
Conditions for value change
P3706, P3705
See Section 11.5 Open Loop Mini Wheel Anti-Drift in User Manual for details on setting parameters.
28 |
©
Danfoss | October 2018
PVED-CLS AUX— soft-stop
AUX soft-stop can decrease flow to cylinders when wheels are close to end-stop to help prevent damage
and jerk. This parameter is used for mini steering wheel and open loop joystick devices.
PVED-CLS soft-stop
on page 25 for configuration details.
Wheels may not return from end-stops or will do so slowly if flow is set too low.
Do not decrease P3708 below 200.
PVED-CLS AUX— anti-jerk
Anti-jerk can be used to decrease jerk in articulated vehicles. These parameters can be applied with a
mini steering wheel or open-loop joystick.
PVED-CLS AUX— anti-drift
Anti-drift can be used to keep the mini steering wheel in the same position when driving straight ahead
by adding a percentage of full flow when the actual mini steering wheel angle does not match the ideal
angle.
AB285975085591en-000101