Application Guide
PVED-CLS startup guide
Parameter setting
Parameter
Conditions for value change
P3730
Max closed loop error [IR, 100=10%] allowed when switching device from AUX to Auto-guidance.
P3731
Minimum time [x10ms] where steady state threshold can't be exceeded to switch device from AUX to Auto-guidance.
P3732
Max closed loop error [IR, 100=10%] before closed loop joystick steering is enabled.
Parameter
Conditions for value change
P3734-P3740
See Section 11.8 in the User Manual for more information
32 |
©
Danfoss | October 2018
PVED-CLS AUX— open loop joystick transfer function
Open Loop Joystick transfer function scales the position of the open loop joystick to a requested flow.