Parameter setting
PVED-CLS vehicle geometry configuration P3421-P3428
Example parameter settings
Parameter
Conditions for value changes
P3421
Set to match type of steering
P3422
Change according to wheel base figure shown below (dimensions measured in mm)
P3424
Change according to wheel base figure shown below (dimensions measured in mm)
P3426
Change according to steer angle figure and formula shown below (measured in degrees)
P3428
Change according to steer angle figure and formula shown below (measured in degrees)
©
Danfoss | October 2018
Navigate to the vehicle geometry configuration section via System Navigator > Configuration >
Vehicle Geometry
If the parameter change is not described below or conditions are not met, use the default values.
Wheel base