Table 5-5 Wireless J-Box And Wireless Hhrc Codes - Will Burt NIGHT SCAN Operator's Manual

Universal remote control system
Table of Contents

Advertisement

Message
Meaning
8,07
Unrecoverable
communication error
8,08
Internal firmware
detected error
8,09
RF module error
8,10
Memory Error
8,11
HHRC power up
negotiation failed
8,12
In-system
reprogramming failed
TP-5543301-C
July 2018
N
S
U
IGHT
CAN
NIVERSAL

Table 5-5 Wireless J-Box and Wireless HHRC Codes

Root Issue
No successful poll / response
communication for 250ms.
Internal state machine logic has
detected an invalid state transition.
XBee plug-in module did not properly
initialize.
Memory Error
Unit could not establish
communication with any HHRC
(wired or wireless) when the NS 3.0 /
4.5 was powered up.
Panel Mount = unit 3, Wireless HHRC
= unit 6, J-Box = unit 8.
System can have a panel mount
remote and an HHRC, or 2 HHRCs,
but never 3 remote units.
Negotiation happens every time the
Base unit is powered up w/push-pull
switch.
Dip-switch activated in-system
reprogramming of attached devices
was not able to successfully
complete.
R
C
S
EMOTE
ONTROL
YSTEM
'
O
M
PERATOR
S
ANUAL
Potential Cause
J-Box is not 'talking' to any
other board. Check Base
Board flashes and HHRC
display for x,07.
Firmware logic error.
Bad module.
Wireless HHRC is not
plugged in during "Pull to
Start" power-up.
5-7

Advertisement

Table of Contents
loading