Meaning
2,13
2,13 Pan Right wrap
around
2,14
2,14 Pan Left wrap around
2,15
Left Tilt Limit Overlap
Right Tilt Limit Overlap
2,16
Message
Meaning
WRN 3,02
Dual HHRC
simultaneous
inputs
3,07
Unrecoverable
Communication
Error
3,08
Microprocessor
Error
3,09
RF module Error
TP-5543301-C
July 2018
N
S
U
IGHT
CAN
NIVERSAL
Root Issue
The software indicates the
same photosensor was made
before the opposite limit
photosensor was made to stop
rotation. This indicates wrap
around.
The software indicates both tilt
photosensors appear to be
blocked simultaneously.

Table 5-3 HHRC Codes

Root Issue
Two HHRCs are sending commands
simultaneously.
If commands are not conflicting, they will
be allowed (Base Board decides).
If commands are conflicting, no
action/movement will be allowed by the
Base Board.
Warning appears regardless of
conflicting or not conflicting to alert
operators that someone else is trying to
operate the unit
The display board in the HHRC or PMRC
has power, but the Base Board is not
communicating with it. It may be caused
by the HHRC, Base Board, RCP Board,
or any other device that is using the RS-
485 communication lines in the system.
On an error, the Base Board stops the
program, sends out the error code to the
display devices and 'flashes' the code on
the Base Board LED. Because one error
can cause others to follow, the only code
that is displayed/flashed is the first one
that occurs. Other errors may happen
after that, but they are not displayed. The
idea is to show the actual initial problem,
rather than any potentially confusing
follow-on errors.
Internal firmware detected error.
Wireless Transmitter/Receiver did not
properly initialize.
R
C
S
EMOTE
ONTROL
YSTEM
Potential Cause
The limit photosensor is
defective.
Foreign material in one of the
photosensors or faulty
photosensor.
simultaneously.
'
O
M
PERATOR
S
ANUAL
Potential Cause
Defective HHRC or defective
base board. Bad or improper
connection in
communications link, or
HHRC is not properly
powered. Check continuity of
the data lines from the DC
power cable connector to the
HHRC connector. Refer to
System schematic. Also
check that the shield in the
junction box has a good
electrical connection to the
electronics common at one
end or the other, but not both.
Replace HHRC or HHRC