2.5.1.4 Wire the Control Box

This section describes wiring the Night Scan Universal Remote Control System. For wiring for
your Night Scan mast, see your Night Scan manual. The Control Box requires a constant 12V
power source separate from the Night Scan mast. This customer power source is required for
wireless remote operation and charging of the Wireless HHRC.
To wire the Control Box (Figure 2-2):
1. Ensure power is removed from the system.
2. Loosen the screws from the cover of the Night Scan mast base.
3. Remove the Night Scan base cover.
4. Run the Night Scan Universal Remote Control System Harness to the Base Board
Universal Control Board (P/N: 4311701) for the Night Scan mast.
5. Connect the Harness to J4 on the Base Board.
6. Replace the base cover.
7. Run customer power (9-36 VDC) to the Deutsch connector (DT15-12PA) on the Control
Box.
8. Run the Harness to the Control Box.
9. Plug the Deutsch connector (DT06-12SA) from the Harness into the Deutsch connector
(DT15-12PA) on the Control Box.
10. As desired, connect the optional Wired HHRC into the terminal on the Control Box.