Table 5-2 Rcp And Positioner Codes - Will Burt NIGHT SCAN Operator's Manual

Universal remote control system
Table of Contents

Advertisement

N
S
U
IGHT
CAN
NIVERSAL
Message
Meaning
WRN 2,04
Single-tilt - Tilt Stuck
Dual-tilt - Left Tilt Stuck
WRN 2,05
Right Tilt Stuck
WRN 2,06
Pan Stuck
2,01
Pan Limit Overlap
2,03
TILT pot stuck
(Positioner
Only)
2,04
PAN pot stuck
(Positioner
Only)
2,07
Communication Timeout
2,08
Microprocessor error
2,09
(Left) Tilt Up wrap around
(RCP Only)
2,10
(Left) Tilt Down wrap
(RCP Only)
around
2,09
Pan Pot Failure
(Positioner
Only)
2,10
Tilt Pot Failure
(Positioner
Only)
2,11
2,11 Right Tilt Up wrap
around
2,12
2,12 Right Tilt Down wrap
around
5-4
R
C
S
EMOTE
ONTROL
YSTEM

Table 5-2 RCP and Positioner Codes

Root Issue
Checked only when moving out
of a limit position. The software
indicates the state of the (left)
tilt photosensor has not
changed even though the motor
has been told to move for more
than 1/2 second.
Checked only when moving out
of a limit position.
The software indicates the state
of the right tilt photosensor has
not changed even though the
motor has been told to move for
more than 1/2 second.
Checked only when moving out
of a limit position.
The software indicates the state
of the pan photosensor has not
changed even though the motor
has been told to move for more
than 1/2 second.
The software indicates both pan
photosensors are blocked
simultaneously.
No movement detected in
expected direction for 2.0
seconds
The RCP or P-T Drive board
has not sent out
communications recently.
The RCP board has sent an
invalid message.
The software indicates the
same photosensor was made
before the opposite limit
photosensor was made to stop
rotation. This indicates wrap
around.
The Positioner software
indicates the pot feedback
voltage is out of acceptable
operating range.
The software indicates the
same photosensor was made
before the opposite limit
photosensor was made to stop
rotation. This indicates wrap
around.
'
O
M
PERATOR
S
ANUAL
Potential Cause
Something is preventing
movement of left tilt
mechanism, the motor is
defective, or the RCP board is
defective.
Something is preventing
movement of right tilt
mechanism, the motor is
defective, or the RCP board is
defective.
Something is preventing
movement of pan mechanism,
the motor is defective, or the
RCP board is defective.
Foreign material in one of the
photosensors or faulty
photosensor.
Soft stops are not set,
something is preventing the
sense voltage (pot) movement,
the motor is defective, the
sense voltage is going the
wrong way (miswire), or the
P/T drive board is defective.
Bad board or connection in
communications link.
Indicates a software problem.
1. The flag that interrupts the
light may need to be adjusted
to go deeper into the photocell.
2. The limit photosensor is
defective
Defective pot, incorrect wiring,
bad connection, defective P-T
board.
1. The flag that interrupts the
light may need to be adjusted
to go deeper into the photocell.
2. The limit photosensor is
defective
TP-5543301-C
July
2018

Advertisement

Table of Contents
loading