Table 5-4 D-Tec Sensor Board Codes - Will Burt NIGHT SCAN Operator's Manual

Universal remote control system
Table of Contents

Advertisement

N
S
U
IGHT
CAN
NIVERSAL
Message
Meaning
5,01
Lamp Fault
5,03
SPI Fault
5,07
Unrecoverable
Communication Error
5,09
E-Field Fault
5,10
H-Field 1 Fault
5,11
H-Field 2 Fault
5,12
H-Field 3 Fault
5,16
Supply Voltage Fault
5-6
R
C
S
EMOTE
ONTROL
YSTEM

Table 5-4 D-TEC Sensor Board Codes

Root Issue
The D-TEC has sensed a fault in the
LED lamp circuit.
A communications bus internal to the
D-TEC sensor has failed during self-
test.
No successful communication for
250ms.
E-Field portion of the D-TEC failed its
self-test.
One axis of the Magnetic Field
portion of the D-TEC failed its self-
test.
One axis of the Magnetic Field
portion of the D-TEC failed its self-
test.
One axis of the Magnetic Field
portion of the D-TEC failed its self-
test.
The power supply section of the D-
TEC sensor is outside proper
operational limits.
'
O
M
PERATOR
S
ANUAL
Potential Cause
This check is made when the
mast thinks it has just arrived
at 90º. The D-TEC Sensor
measures the current through
the look-up LED's to see if it
is within a certain range. If it
is not, the fault occurs.
Defective Sensor
Check connection (data lines,
ground) for continuity.
This error may also be
displayed on systems without
a D-TEC if the Base Board is
missing the 4710801 DIP
Switch Shunt Board.
Defective sensor
Defective sensor
Defective sensor
Defective sensor
Check power connections,
voltage level and induced
noise on power source.
TP-5543301-C
July
2018

Advertisement

Table of Contents
loading

Table of Contents