Technical Specifications; Master Station; Actuator Field Units - rotork Pakscan IIE System Manual

Table of Contents

Advertisement

16 TECHNICAL SPECIFICATIONS

16.1 Master Station

Enclosure
Supply Voltage
Power Consumption
Current Loop
Cable
Field Units
Host Communications (RS232 or RS485)
Connector
Protocol
Format
Baud rate
Parity
Stop Bits
Host Communications (Ethernet option)
Connector
Protocol
Loop Connections
Power Connection
Environmental Spec
Relay Contacts

16.2 Actuator Field Units

For data on field units fitted inside Rotork actuators refer to the actuator or field unit data sheets. The
integral field units operate in the same environment as the actuator, using the actuator power supply
and communicating commands and data directly with the actuator electronics.
121 of 132
19" rack to DIN41494 with rear terminals and connectors
90 to 264V ac, 43 to 440Hz, Fuse 1 Amp
30VA for each master station module, 60VA for a hot standby
master station
20mA 15V max, Pakscan protocol
Single twisted pair, 500 Ω max resistance and 3.9 µ F max
capacitance
240 max Actuator and General Purpose field units
9 way D type
Modbus RTU
Asynchronous
1200, 2400, 4800, 9600, and 19200
Odd, Even, None or Always 0
1
RJ45
Modbus TCP
Screw clamp terminals suitable for 1.5
IEC connector
Operating Temperature -10 to 60
Storage Temperature -10 to +70
Humidity 5% to 95% RH non-condensing
300 mA at 24V dc or 130 mA at 125V ac
Publication S177E V2.0 Issue 03/05
Technical Specifications
2
mm cables
o
C
o
C