Renesas REG10J0020-0200 User Manual
Renesas REG10J0020-0200 User Manual

Renesas REG10J0020-0200 User Manual

Starter kit lcd application board

Advertisement

Quick Links

REG10J0020-0200
Renesas Starter Kit LCD Application Board
User's Manual
Rev.2.00
Revision date:29.11.2007
RENESAS STARTER KIT
Renesas Technology Europe Ltd.
www.renesas.com

Advertisement

Table of Contents
loading

Summary of Contents for Renesas REG10J0020-0200

  • Page 1 REG10J0020-0200 Renesas Starter Kit LCD Application Board User's Manual Rev.2.00 Revision date:29.11.2007 RENESAS STARTER KIT Renesas Technology Europe Ltd. www.renesas.com...
  • Page 2: Table Of Contents

    Table of Contents Chapter 1. Preface ...3 Chapter 2. Purpose ...4 Chapter 3. Board Layout ...5 3.1. Component References ...5 3.2. Board Component functions...6 3.3. Board Dimensions ...7 Chapter 4. User Circuitry...8 4.1. Fitting the Target RSK to the RSK LCD application board ...8 4.2.
  • Page 3: Chapter 1. Preface

    Cautions This document may be, wholly or partially, subject to change without notice. All rights reserved. Duplication of this document, either in whole or part is prohibited without the written permission of Renesas Technology Europe Limited. Trademarks All brand or product names used in this manual are trademarks or registered trademarks of their respective companies or organisations.
  • Page 4: Chapter 2.Purpose

    This RSK Application Board is an evaluation tool for Renesas microcontrollers with an LCD driver interface. It is used in conjunction with the RSK for the microcontroller to be evaluated. Features include: • Mounting connections to allow RSK to be added to top of board.
  • Page 5: Chapter 3.Board Layout

    Chapter 3.Board Layout 3.1.Component References The following diagram shows the component references for the board. Figure 3-1: Component References...
  • Page 6: Board Component Functions

    3.2.Board Component functions The following diagram the shows the functions of the components on the board. Switch Coin Cell Holder Caution: If processor is not in low power mode at start up the battery life will be significantly reduced. Application Board Interface Application Board Interface Figure 3-2: Board Layout J A4...
  • Page 7: Board Dimensions

    3.3.Board Dimensions The following diagram gives the board dimensions and connector positions. All through hole connectors are on a common 0.1” grid for easy interfacing. 50.80 mm 27.00mm 45.00mm 170.00mm 115.00mm 86.36mm Figure 3-3 : Board Dimensions Corners x4 radius Coin Cell Holder...
  • Page 8: Chapter 4.User Circuitry

    Chapter 4.User Circuitry 4.1.Fitting the Target RSK to the RSK LCD application board The board is supplied with 2x 24 way sockets, 2x 26 way sockets and 1 x 50 way socket. These should be soldered on the underside of the host RSK in JA1, JA2, JA5, JA6 and JA4 positions. The RSK should be plugged into the equivalent connectors on the RSK LCD application board.
  • Page 9 Segment Bit number Table 4-1: LCD character maps Hex value for RAM 4762 A1E2 01E0 0065 41E2 4162 81E0 4662 1188 0680 A062 00E0 2661 8661 07E0 4362 87E0 C362 1108 45A2 06E0 8601 8664 A005 2009 2184 07E0 1008 43C2 4782 4622...
  • Page 10: Coin Cell And Switch

    4.3.Coin Cell and switch. The board includes a coin cell holder to hold a 2032 3.6V coin cell. To power the attached RSK from this cell the switch must be in the “ON” position. IT IS IMPORTANT NOT TO POWER THE ATTACHED RSK VIA THE POWER SUPPLY JACK OR VIA THE E8A IF THIS OPTION IS USED.
  • Page 11: Chapter 5.Headers

    5.1.Application Headers This information is supplied for reference. Only JA1 pin 3 (battery supply voltage to RSK) and the ground pins are connected on this board. Table 5-1 and Generic Header Name Regulated Supply 1 Regulated Supply 2 Analogue Supply Analogue Reference ADC0 ADC2...
  • Page 12 Generic Header Name CPU board Signal Name Open drain Open drain Open drain output Open drain Open drain Up/down Motor control Motor control Motor control Output Input Open drain SPARE Table 5-2: JA2 Standard Generic Header Table 5-3 and Table 5-4 below show the optional generic header connections Generic Header Name CPU board Signal Name...
  • Page 13 Generic Header Name Host Serial SCIdTX Serial Port Serial Port Synchronous Serial Port Synchronous Reserved Reserved Reserved Reserved Reserved Reserved Table 5-4: JA6 Optional Generic Header CPU board Header Name Signal Name DREQ TEND Standby (Open drain) RS232TX Host Serial SCIbRX Serial Port SCIcTX...
  • Page 14 Table 5-5 below shows the LCD header connections Generic Header Name Signal Name GROUND GROUND COM1 COM1 COM3 COM3 SEG1 SEG1 SEG3 SEG3 SEG5 SEG5 SEG7 SEG7 SEG9 SEG9 SEG11 SEG11 SEG13 SEG13 SEG15 SEG15 SEG17 SEG17 SEG19 SEG19 SEG21 SEG21 SEG23 SEG23...
  • Page 15: Chapter 6.Code Development

    Chapter 6.Code Development RSKs with appropriate LCD connections will include suitable sample software to drive the LCD on this board. Section 4.2 includes details of bit mapping for the LCD segments.
  • Page 16: Chapter 7.Additional Information

    For details on how to use High-performance Embedded Workshop (HEW), refer to the HEW manual available on the CD or from the web site. Online technical support and information is available at: Technical Contact Details America: techsupport.rta@renesas.com Europe: tools.support.eu@renesas.com Japan: csc@renesas.com General information on Renesas Microcontrollers can be found on the Renesas website at: http://www.renesas.com/renesas_starter_kits http://www.renesas.com/...
  • Page 17 Renesas Starter Kit LCD Application Board User's Manual Publication Date Rev.2.00 29.11.2007 Published by: Renesas Technology Europe Ltd. Duke’s Meadow, Millboard Road, Bourne End Buckinghamshire SL8 5FH, United Kingdom ©2007 Renesas Technology Europe and Renesas Solutions Corp., All Rights Reserved.
  • Page 18 Renesas Starter LCD Application Board User's Manual Renesas Technology Europe Ltd. Duke’s Meadow, Millboard Road, Bourne End Buckinghamshire SL8 5FH, United Kingdom...