Keysight Technologies N9030A Installation Note
Keysight Technologies N9030A Installation Note

Keysight Technologies N9030A Installation Note

Pxa signal analyzer. option mtu, multitouch user interface upgrade kit option mtp, multitouch user interface upgrade kit with pc6 cpu
Hide thumbs Also See for N9030A:

Advertisement

Quick Links

Keysight Technologies
N9030A PXA Signal Analyzer
Option MTU, MultiTouch User Interface Upgrade Kit
Option MTP, MultiTouch User Interface Upgrade Kit
with PC6 CPU
Installation Note

Advertisement

Table of Contents
loading

Summary of Contents for Keysight Technologies N9030A

  • Page 1 Keysight Technologies N9030A PXA Signal Analyzer Option MTU, MultiTouch User Interface Upgrade Kit Option MTP, MultiTouch User Interface Upgrade Kit with PC6 CPU Installation Note...
  • Page 2 The information contained in this document is subject to change without notice. Keysight Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3 4.0 Hours Introduction This installation note explains how to install the hardware and licenses to add the MultiTouch user interface to N9030A PXA signal analyzers. This installation note supports two kits: N9030AK-MTU - MultiTouch User Interface Upgrade N9030AK-MTP - MultiTouch User Interface Upgrade with PC6 CPU The N9030AK-MTU should only be installed on N9030As that already have the PC6 CPU.
  • Page 4 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Once this upgrade is performed, the analyzer will only recognize IMPORTANT measurement applications whose model number ends in a "C". For example, the N9068C, Phase Noise measurement application or the N9071C GSM/EDGE measurement application.
  • Page 5: N9030Ak-Mtu, Multitouch User Interface Upgrade Kit Parts List

    Overlay, Connector, Blank, quartz gray N9020-80140 Overlay, Keypad, quartz gray N9020-80165 Entitlement Certificate 5964-5178 Entitlement Certificate Envelope 5967-7169 Installation Note This note a. This trim strip is not used for the N9030A; Opt PRC is not supported on the N9030A Installation Note N9030-90098...
  • Page 6: N9030Ak-Mtp, Multitouch User Interface With Pc6 Cpu Upgrade Kit Parts List

    Overlay, Connector, Blank, quartz gray N9020-80140 Overlay, Keypad, quartz gray N9020-80165 Entitlement Certificate 5964-5178 Entitlement Certificate Envelope 5967-7169 Installation Note This note a. This trim strip is not used for the N9030A; Opt PRC is not supported on the N9030A Installation Note N9030-90098...
  • Page 7: Tools Required

    Option MTU and MTP, MultiTouch User Interface Upgrade Kits Tools Required — T-10 TORX Driver — T-20 TORX Driver — 5/16-inch torque wrench — Deep 5/16-inch socket wrench — ¼-inch open-end wrench — Scissors or knife — Diagonal cutters — Microsoft Windows based personal computer with internet access and USB port —...
  • Page 8: Installation Procedure

    4. Refer to the data in step 2 above. If the Product Number is not N9030A, do not proceed with the installation of this kit. This kit is to be installed only on N9030A signal analyzers. 5. Refer to the data in step 3 above.
  • Page 9 Option MTU and MTP, MultiTouch User Interface Upgrade Kits License Key Backup In order for the instrument being upgraded to keep the same option configuration that it had prior to the upgrade, it is mandatory that the licenses be transferred from the original disk drive to the new disk drive.
  • Page 10 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Backup Calibration Data 1. With the instrument turned on and the signal analyzer application running as normal, connect a USB mouse to one of the instrument USB ports. 2. Locate a USB storage device and insert it into one of the available instrument USB ports. (Perform a virus scan on this device before use) 3.
  • Page 11 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Replacing Solid State Drive (SSD) - N9030A-MTU Upgrade Only The steps in this section apply only to N9030A-MTU upgrades, where the solid state drive is replaced. If the N9030A-MTP upgrade is being performed, skip to"...
  • Page 12 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 3. Refer to Figure 3. Remove the 4 machine screws (1) from the disk drive carrier assembly that secure the drive (2). Figure 3 Disk Drive Screws 4. Remove the disk drive (2) from the carrier assembly. 5.
  • Page 13 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Replacing CPU Assembly - N9030A-MTP Upgrade Only The steps in this section apply only to N9030A-MTP upgrades, where the CPU is replaced. If the N9030A-MTU upgrade is being performed, skip to "Replacing Solid State Drive (SSD) -...
  • Page 14 The instrument may require more than 5 minutes to power-on. This is affected by the operating system initial start-up requirements. 3. The Keysight Technologies screen appears followed by a screen that automatically loads the operating system. 4. The License Agreement dialog box as shown in...
  • Page 15 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Figure 5 License Agreement Dialog Box Select Agree to continue, or Do Not Agree to turn off the instrument before initializing the software. After launching the setup, do not turn off the instrument or remove power before the setup routine completes and the system restarts.
  • Page 16 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 6. The anti-virus notification as shown in Figure 7 will then appear. Figure 7 Anti-Virus Message If you do not check the "Do not show this message again" check box, this message will be displayed each time the instrument is turned on.
  • Page 17 Option MTU and MTP, MultiTouch User Interface Upgrade Kits License Key Restore 1. Insert the USB storage device containing the backed-up license key. 2. Navigate to the "Licenses_.." folder on the USB storage device that is for the instrument being upgraded.
  • Page 18: Software Updates

    Option MTU and MTP, MultiTouch User Interface Upgrade Kits Software Updates The currently installed instrument software version can be easily determined by pressing the following front panel keys: System, Show, System The software revision can be found on this screen as the: Instrument S/W Revision Updating the Instrument Software: 1.
  • Page 19 Option MTU and MTP, MultiTouch User Interface Upgrade Kits FPGA Code Update If the instrument software was updated in the previous section, it is not necessary to also do the FPGA Code Update; this update is performed as part of the instrument software update. If the instrument software was not updated, continue with the procedure below.
  • Page 20 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 5. To program the FPGA code enter 1 and press Enter. You will need to confirm this selection by selecting 1 and Enter one more time. 6. The programming of the FPGA code could take a few minutes to complete. Once it has finished the instrument will reboot itself to use the new code.
  • Page 21 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Data Restore 1. With the instrument turned on and the signal analyzer application running as normal, connect a USB mouse to one of the instrument USB ports. 2. Connect the USB memory device that was earlier used to backup the instrument calibration data to one of the instrument USB ports.
  • Page 22 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Calibration Data Backup to SD Card The PC6 processor assembly contains an internal SD card for the purpose of providing a location to back up the calibration data. After the PC6 assembly is installed and the calibration data from the previously installed processor assembly has been restored, another backup should be performed, this time to the SD card.
  • Page 23 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Redeeming Entitlement Certificate and Deleting Migrated Licenses 1. Locate the Option Upgrade Entitlement Certificate (5964-5178) from the kit. 2. Redeem the Option Upgrade Entitlement Certificate by following the instructions on the Certificate.
  • Page 24 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 7. Connect the USB Storage Device to one of the analyzer's USB ports. Windows will detect the new hardware and may display the configuration menu shown in Figure 11. This menu may be configured according to your preferences.
  • Page 25: Analyzer Disassembly

    Option MTU and MTP, MultiTouch User Interface Upgrade Kits Analyzer Disassembly If the instrument is placed on its face during any of the following procedures, be sure to use a soft surface or soft cloth to avoid damage to the front panel, keys, or input connector. Make sure any adapters on the front panel are removed.
  • Page 26 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Remove Outer Case 1. Disconnect the instrument from ac power. 2. Refer to Figure 13. Using the T-20 driver, remove the four screws (two on each side) (1) that attach the handle strap (2) on each side of the instrument. 3.
  • Page 27 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Front Frame Assembly Removal 1. If the PXA has Option EXM, External Mixer, use a ¼" open end wrench and 5/16" open end wrench to disconnect semi-rigid coax cable W29 from W17. 2.
  • Page 28 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 3. Refer to Figure 15. Pull the front frame carefully away from the chassis. Remove the ribbon cable W1 from the A8 Motherboard. W1 may have locking springs on each side. Depress the spring on each side of the connector to remove from the motherboard.
  • Page 29 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Removal of Option BBA Parts from Original Front Frame Assembly This procedure applies only to instruments with Option BBA, BBIQ Analog Inputs 1. Refer to Figure 16. Remove the single 0515-1035 (1) screw that secures the BBIQ Interface Board to the side of the frame.
  • Page 30 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 2. Refer to Figure 17. Remove the two 0515-0372 screws (2) that secure the BBIQ Interface Board (1) to the front frame. Figure 17 Remove BBIQ Interface Board 3. Remove the BBIQ Interface Board (1) by pulling the board out from behind the front frame. The BBIQ Interface board will be re-used.
  • Page 31 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 4. Refer to Figure 18. Peel off the top BBIQ overlay from the front frame assembly. Figure 18 Remove BBIQ Top Overlay Installation Note N9030-90098...
  • Page 32 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 5. Refer to Figure 19. Remove the LED board by removing the two 0515-1227 screws (2). 6. If the bottom BBIQ overlay did not peel off with the top overlay, peel off the bottom BBIQ overlay from the LED board.
  • Page 33: Removal Of Option Exm, External Mixing Parts From Original Front Frame

    Option MTU and MTP, MultiTouch User Interface Upgrade Kits Removal of Option EXM, External Mixing Parts from Original Front Frame This procedure applies only to instruments with Option EXM, External Mixing 1. Refer to Figure 20. Disconnect semi-rigid coax cable W29 from the Ext Mixer connector using a 5/16 inch open-end wrench.
  • Page 34 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 2. Refer to Figure 21. Use a deep 5/16-inch socket wrench to loosen and remove the ¼" hex nut (2950-0223) and ¼" lock washer (2190-0067) on the inside of the front frame that is attaching the Ext Mixer connector to the front frame.
  • Page 35: Prepare New Front Frame Assembly

    1. Locate the new Front Frame Assembly (N9020-60261) in the kit. 2. The kit includes two Keypad Overlays, however only one is needed for use with the N9030A. Locate the Overlay, Keypad (N9020-80165). This will be the overlay with the hole in the upper right corner labeled EXT MIXER.
  • Page 36: Add Ext Mixer Connector And Cable To Front Frame Assembly

    Option MTU and MTP, MultiTouch User Interface Upgrade Kits Add EXT MIXER Connector and Cable to Front Frame Assembly This procedure applies only to analyzers with Option EXM, External Mixer. Proceed to the next section if Option EXM is not installed. 1.
  • Page 37 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 4. Connect one end of W29 to the SMA female connector as shown in Figure 5. Orient W29 so that the cable slopes upward from the Ext Mixer connector at a 15 degree angle.
  • Page 38: Led Board And Overlay Installation

    Option MTU and MTP, MultiTouch User Interface Upgrade Kits LED Board and Overlay Installation This procedure only applies to analyzers with Option BBA, BBIQ Analog Inputs. If the analyzer does not have Option BBA, proceed to the next section. 1. Remove the filter plate to the left of the display. The screws will be re-used, but the filler plate will not be re-used.
  • Page 39 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 3. Refer to Figure 25. Line up the holes and carefully attach the N9020-80193 overlay to the LED board. 4. Refer to Figure 26. Install the LED board with overlay attached (1) into the front frame. 5.
  • Page 40 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 6. Refer to Figure 27. Line up and carefully attach the top overlay N9020-80192 over the lower overlay. 7. Press firmly down over the entire surface area of the top overlay. Figure 27 Overlay Alignment Installation Note N9030-90098...
  • Page 41 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 8. Refer to Figure 28. Install the BBIQ Interface Board that was removed from the original front frame assembly into the front frame passing the BNC connectors through the holes. 9. Secure the BBIQ Interface Board with two 0515-0372 screws (2) that were removed earlier. Torque to 9 in-lbs.
  • Page 42 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 10.Refer to Figure 29. Secure the BBIQ Interface Board to the side of the front frame with a single 0515-2032 screw (1) removed earlier. Torque to 9 in-lbs. Figure 29 BBIQ Interface Board Side Screw Installation Installation Note N9030-90098...
  • Page 43 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 11.Refer to Figure 30. Connect the ribbon to the BBIQ Interface Board. 12.Install two N9020-20017 Hex screws (1) to secure the flex ribbon into the connector. Torque to 4 in-lbs with the ¼-inch socket. Figure 30 Inverter Ribbon Cable Installation Installation Note N9030-90098...
  • Page 44 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 13.Refer to Figure 31. Cut the Vibration Mount 0460-2725 (3) supplied in the kit into four pieces with scissors or a knife to fit the Core Bracket, Top (2) N9020-00071 and the Core Bracket, Bottom (4) N9020-00072.
  • Page 45: New Front Frame Installation

    Option MTU and MTP, MultiTouch User Interface Upgrade Kits New Front Frame Installation 1. Refer to Figure 32. Reattach the ribbon cable W1. Ensure the locking tabs are engaged. 2. Carefully install the front panel assembly making sure that the ribbon cables are not pinched. Also, if Option BBA is installed, align the BBIQ Interface Board properly so the components do not become damaged by the fan bracket sheet metal.
  • Page 46 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 3. Refer to Figure 33. Carefully position the Front Frame Assembly onto the chassis. Ensure no cables are crushed. Secure with the eight screws (0515-2032) (1) included in the kit, four on each side of the chassis.
  • Page 47 Option MTU and MTP, MultiTouch User Interface Upgrade Kits 4. If Option EXM, External Mixing, is not installed, skip steps 5 through 7. 5. Refer to Figure 34. When the front panel is installed, cables W29 and W17 typically do not align.
  • Page 48 Option MTU and MTP, MultiTouch User Interface Upgrade Kits Figure 35 W29 and W17 Properly Aligned 7. Refer to Figure 36. Use a ¼” open-end wrench to prevent the SMA female connector on W17 from twisting. Use a 5/16” torque wrench to torque the nut on W29 to 10 inch-pounds. Figure 36 Torque Cable W17 onto W29 8.
  • Page 49: Final Installation

    Connect the 50 Ω termination to the EXT MIXER connector. Verify Hardware Installation 1. Verify the spectrum analyzer application loads and sweeps as expected. 2. Press System, Show Hard ware on the analyzer and verify that Option N9030A-MTU, Multi-touch user interface, is installed. Installation Note N9030-90098...
  • Page 50: Adjustments, And Performance Verification

    None (if the Calibration data file was backed-up and restored). For assistance, contact your nearest Keysight Technologies Sales and Service Office. To find your local Keysight office access the following URL, or if in the United States, call the following telephone number: http://www.keysight.com/find/assist...
  • Page 51 This information is subject to change without notice. © Keysight Technologies 2016 Edition 1, July 2016 N9030-90098 www.keysight.com...