5 Creating Measurement Scenes
Checking Variables
Check which variable is assigned to which processing unit and whether or not there is an undefined
variable.
1
On the Variable button area, click
The "Variable assignment list" window is displayed.
The window displays the assignment list of the Scene variables and System variables in use.
Additional Information
The following operation also enables variables to check. If there are undefined variables, a
warning dialog box will be displayed.
• Click [Variable check] in the shortcut menu displayed when clicking [Edit flow] in the Menu
bar.
• Click [Variable check] icon on the Edit flow button area.
2
Check assigned variables in the "Variable assignment list" window.
 When variables are assigned to processing units:
A "+" is displayed at the head of the variable.
Clicking the "+" displays the assigned processing unit name.
Clicking the "+" at the head of the processing unit displays its parameters.
Double-clicking a variable displays the "Scene variable" tab screen or "System variable" tab screen
depending on the variable.
Double-clicking the processing unit displays a parameter area of the variable on the Edit flow
screen.
Check the processing unit and its assigned parameter values.
5 - 64
[Variable assignment list].