10 Advanced Usage

10-9-2 Execution of Calibration

This section uses two Cameras and a stage as the external device to describe an example for setting
the calibration flow and executing calibration.
Example: Calibration Flow Example for 2 Cameras
Camera Image Input processing item
Machine setting processing item
Position measurement processing item
Camera Switching processing item
Position measurement processing item
Calibration processing items
Data output processing items
10 - 52
· · · Select Camera 0.
· · · Register [stage data] or [robot data] depending on the external
· · · Measure the position of the alignment marks to use as the sam-
· · · Select Camera 1.
· · · Measure the position of the alignment marks to use as the sam-
· · · Register [Vision Master Calibration] or [PLC Master Calibration].
· · · Depending on the communications method, register either [Data
device to be used, and then set the information for the external
device.
The machine setting processing item can be placed anywhere in
the measurement flow other than at the beginning of the mea-
surement flow.
pling target, or the position of a special feature (such as corners)
of the workpiece from the image in Camera 0.
To output the position on the image, set [Calibration] on the [Out-
put parameter] tab page to OFF.
pling target, or the position of a special feature (such as corners)
of the workpiece from the image in Camera 1.
To output the position on the image, set [Calibration] on the [Out-
put parameter] tab page to OFF.
Set the machine setting processing item to reference, and then
set the sampling.
output] or [Fieldbus data output].
The Vision Master Calibration processing item may send three
parameters to the PLC: [Axis movement required for sampling],
[Origin return], and [Completion Timing of Calibration].
Each parameter is output after a reference of the calculation for
the Vision Master Calibration processing item is made.
With the PLC Master Calibration processing item, it is not neces-
sary to send data to the PLC, so Data Output processing items
are not necessary.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)