2-5-9 Wiring for Auto-reset (Interlock is Invalid)

(Wiring Example of the Control Category 4)
<For PNP output>
Gray cable
Gray cable
with black line
Interlock function
External device monitor function Valid
Auxiliary output
The device output is selected depending on the connecting state of the output polarity setting wire
(shield). Incorrect wiring may cause the lockout state.
* Symbols
Switch S1
9V WR 9V  9 VLQN FXUUHQW P$ RU OHVV  (PLVVLRQ 1RWH   2SHQ (PLVVLRQ KDOW
. . ([WHUQDO GHYLFH )RUFHG JXLGHG UHOD\ RU PDJQHWLF FRQWDFWRU
1RWHV  9V LV WKH DSSO\LQJ VXSSO\ YROWDJH
2) The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, gray, gray /
black, sky-blue / white, sky-blue / black, there is no lead wire.
3) For resetting, refer to "3-2 Interlock Function."
51
(Gray) Interference prevention +
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Yellow) Override input
(Pale purple) Interlock setting input
(Brown) +V
(Pink) Emission halt input / Reset input
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-bule / White) Muting input A
(Sky-bule / Black) Muting input B
(Gray / Black) Interference prevention -
(Gray) Interference prevention +
Invalid (Auto-reset)
Can be used
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
*S1
+
Load
-
K1
K2
K1
K2
24V DC
±10 %