2-5-4 Basic Wiring

7KLV LV WKH JHQHUDO FRQ¿JXUDWLRQ XVLQJ RQH VHW RI WKH HPLWWHU DQG UHFHLYHU IDFLQJ HDFK RWKHU
The control output (OSSD 1 / 2) turns OFF if the light is blocked, while it automatically turns ON
if receives the light.
The auxiliary output is used to invalid the external device monitor function. At this time, set the
auxiliary output with "negative logic of the control output" (factory setting). The auxiliary output
cannot be connected to external devices.
<For PNP output>
Gray cable
Gray cable
with black line
Interlock function
External device monitor function Invalid
Auxiliary output
1RWH 7KH FLUFXLW GLDJUDP VKRZQ DERYH LV IRU FRUH FDEOH WR EH XVHG )RU FRUH FDEOH UHG \HOORZ JUD\ JUD\ 
black, sky-blue / white, sky-blue / black, there is no lead wire.
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
(Gray) Interference prevention +
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Yellow) Override input
(Pale purple) Interlock setting input
(Brown) +V
(Pink) Emission halt input / Reset input
(Shield) Output polarity setting wire
(Blue) 0V
(Yellow-green / Black) Auxiliary output
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-bule / White) Muting input A
(Sky-bule / Black) Muting input B
(Gray / Black) Interference prevention -
(Gray) Interference prevention +
Invalid (Auto-reset)
Cannot be used
+
-
K1
K2
24V DC
±10 %