[In Chinese standard (GB 4584)]
In case slide of press machine can be stopped where you would like to, safety distance S
can be calculate by calculating formula 1.
Equation 1
6
6DIHW\ GLVWDQFH PP
Minimum required distance between the sensing area surface and the danger-
ous parts of the machine.
.
,QWUXVLRQ YHORFLW\ RI RSHUDWRU¶V ERG\ RU REMHFW PPVHF
In case the intrusion direction is horizontal to the sensing area, Taken as 1,600 (mm/
sec.) for calculation. In case the intrusion direction is perpendicular to the sensing area,
Taken as 2,000 (mm/sec.) for calculation when the safety distance is 500mm/s or less
and taken as 1,600 (mm/sec.) for calculation when safety distance is 500mm/s or more.
7
5HVSRQVH WLPH RI WRWDO HTXLSPHQW VHF
T = T
&
'LVWDQFH IURP HQWHULQJ KDQG WR WKH VHQVLQJ DUHD WR WKLV SURGXFW VHQVLQJ LW PP
Calculate based on table below in case not using interlock function (start-restart
interlock) of this device or safety controller in press machine.
Minimum sensing object
In case using interlock function (start-restart interlock) of this device or safety con-
troller etc. in press machine, C equals 0.
In case the slide of press machine can not be stopped in your desire point, the safety
distance S can be calculated from formula 2.
Equation 1
6
6DIHW\ GLVWDQFH PP
Minimum required distance between the sensing area surface and the danger-
ous parts of the machine.
.
,QWUXVLRQ YHORFLW\ RI RSHUDWRU¶V ERG\ RU REMHFW PPVHF
In case the intrusion direction is horizontal to the sensing area, Taken as 1,600 (mm/
sec.) for calculation. In case the intrusion direction is perpendicular to the sensing area,
Taken as 2,000 (mm/sec.) for calculation when the safety distance is 500mm/s or less
and taken as 1,600 (mm/sec.) for calculation when safety distance is 500mm/s or more.
T
7LPH IURP HQWHULQJ KDQG WR WKLV GHYLFH WR VOLGH UHDFKLQJ ERWWRP GHDG SRLQW V
S
T
S
1 1XPEHU RI FKDVHV RI FOXWFK
T
n
&
'LVWDQFH IURP HQWHULQJ KDQG WR WKH VHQVLQJ DUHD WR WKLV SURGXFW VHQVLQJ LW PP
Calculate based on table below in case not using interlock function (start-restart
interlock) of this device or safety controller in press machine.
Minimum sensing object
In case using interlock function (start-restart interlock) of this device or safety con-
troller etc. in press machine, C equals 0.
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
S = K × T + C
+ T
m
SF4B
T
0D[LPXP KDOWLQJ WLPH RI PDFKLQH VHF
m
T
5HVSRQVH WLPH RI WKLV GHYLFH VHF
SF4B
14mm or less
14 to 20mm
20 to 30mm
30 to 40mm
40mm ot more
S = K × T + C
= [(1 / 2 ) + (1 / N)] × T
7LPH RI JRLQJ LQWR D GHJUHH UROO V
14mm or less
14 to 20mm
20 to 30mm
30 to 40mm
40mm ot more
Additional distance C
0mm
80mm
130mm
240mm
850mm
n
Additional distance C
0mm
80mm
130mm
240mm
850mm
Stroke starting by this device or safety
controller etc.
Possible
Not possible
Stroke starting by this device or safety
controller etc.
Possible
Not possible
18