Chapter 4 Maintenance; Daily Inspection - Panasonic SF4B V2 Series Instruction Manual

Light curtain type 4
Hide thumbs Also See for SF4B V2 Series:
Table of Contents

Advertisement

Chapter 4 Maintenance

<Reference>
When any errors are found, refer to "Chapter 5 Troubleshooting" and report the symptoms to the main-
WHQDQFH LQ FKDUJH ,I WKH UHFWL¿FDWLRQ PHWKRG LV QRW FOHDU SOHDVH FRQWDFW RXU RI¿FH
3OHDVH PDNH D FRS\ RI WKLV FKHFNOLVW FKHFN HDFK LQVSHFWLRQ LWHP LQ WKH UHVSHFWLYH VTXDUH DQG ¿OH WKH OLVW
for record.

4-1 Daily Inspection

Check list (Daily inspection)
Check
column
Dangerous parts of the machine cannot be reached without passing through the sensing area of
this device.
Some part of operator's body remains in the sensing area when operation is done with dangerous
parts of the machine.
The calculated safety distance has been maintained or exceeded during installation.
There is no damage to the safety guard or protective structure.
There is no defect, fold, or damage in the wiring.
The corresponding connectors have been connected securely.
No dirt or scratches exist on the light emitting surface.
The test rod is not deformed or defective.
The operation indicator (green) of the emitter and the OSSD indicator (green) of the receiver light
up when no object is present in the sensing area. The control output (OSSD 1 / 2) is in ON status.
At this time, the effect of external noise can be inspected. In case external noise affects the opera-
tion, remove its cause and reinspect.
The test rod (ø14mm for 6)%) 9!, ø25mm for 6)%+ 9!, ø45mm for 6)%$ 9!)
can be detected less than 1,600mm/sec. at three positions, directly in front of the emitter (A), mid-
way between the emitter and the receiver (B), and directly in front of the receiver (C).
The OSSD indicator (red) of the receiver and the operation indicator (red) of the emitter continue
to light up as long as the test rod is present in the sensing area from (A) to (C).
With the machine in the operating condition, the dangerous parts operate normally when no object
is present in the sensing area.
With the machine in the operating condition, the dangerous parts stop immediately when the test
rod is inserted into the sensing area at any of the three positions, directly in front of the emitter (A),
midway between the emitter and the receiver (B), and directly in front of the receiver (C).
The dangerous parts remain stopped as long as the test rod is present in the sensing area.
The dangerous parts stop immediately when the power supply of this device is turned OFF.
The control output (OSSD 1 / 2) must turn OFF when the emission halt input / reset input wire (pink)
LV RSHQ IRU PDQXDO UHVHW FRQQHFWHG WR 9 9  $W WKLV WLPH WKH HIIHFW RI H[WHUQDO QRLVH FDQ EH
inspected. In case external noise affects the operation, remove its cause and reinspect.
Be sure to check the operation of the muting function before its use. Furthermore, check the state
of the muting lamp (cleanliness or brightness etc.).
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
%H VXUH WR LQVSHFW WKH IROORZLQJ LWHPV SULRU WR RSHUDWLRQ DQG FRQ¿UP WKDW WKHUH LV
no error.
Operating this device without inspection or in an error condition can result in
death or serious injury.
Inspection item
(A)
(B)
(C)
Test rod