Panasonic SF4B V2 Series Instruction Manual page 73

Light curtain type 4
Hide thumbs Also See for SF4B V2 Series:
Table of Contents

Advertisement

<Output operation of muting sensors>
NO (Normally Open) type
ON with light non-received status
(photoelectric sensor, etc.)
ON with object approaching status
(inductive proximity sensor, etc.)
ON with object contacted status
(position switch, etc.)
<Installation condition example of muting sensors>
Muting sensor B
Muting sensor A
Guard
Sensing object
Guard
1) Shorten the distances between muting sensors A to C and between B to D than the whole length of the sensing object.
2) The time of the sensing object to be passed through the muting sensors A to B shall be 0.03 to under 3 sec.
Distance between A and B (m) < S (m/sec.) × 3 (sec.)
6 7KH PRYLQJ VSHHG PVHF RI WKH VHQVLQJ REMHFW
3) The time of the sensing object to be passed through the muting sensors C to D shall be under 3 sec.
Distance between C and D (m) < S (m/sec.) × 3 (sec.)
6 7KH PRYLQJ VSHHG PVHF RI WKH VHQVLQJ REMHFW
<For PNP output>
Muting
sensor A
+V
Muting input A
<For NPN output>
Muting
sensor A
0V
Muting input A
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
Operation at ON state Operation at OFF state
Output 0V or +V
%H VXUH WR XVH D PXWLQJ VHQVRU WKDW VDWLV¿HV WKH <Output operation of muting
sensors> DERYH ,I WKH RWKHU PXWLQJ VHQVRU QRW VDWLVI\LQJ WKH VSHFL¿FDWLRQ DERYH
the muting function might become valid with the timing that the machine designer
cannot expect and could result in death or serious injury.
Light curtain Muting sensor C
S (m/sec)
1
1
2
Safety zone
Muting
sensor C
Muting
sensor C
0V
Muting sensor D
3
Dangerous zone
Muting
sensor B
+V
Muting input B
Muting
sensor B
0V
Muting input B
Open
Muting
sensor D
Muting
sensor D
0V
72

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf4b-f*v2Sf4b-h*v2Sf4b-a*v2

Table of Contents