2-6 Adjustment

2-6-1

Beam-axis Alignment

1. Turn ON the power supply unit of this device.
2. Check that the digital error indicator (red) and the fault indicator (yellow) of the emitter and
receiver are OFF respectively.
If the digital error indicator (red) or the fault indicator (yellow) lights up or blinks, refer to
"Chapter 5 Troubleshooting," and report the symptoms to the maintenance in charge.
3. In case of using the intermediate supporting bracket (MS-SFB-2), loosen the two hexagon-
socket head bolt [M5 (purchase separately)].
4. Loosen the hexagon-socket head bolt for beam axis alignment of the mounting bracket, and
adjust the emitter / receiver so that the beam-axis alignment indicators in the display of the
emitter and receiver light up.
7KH HPLWWHU DQG WKH UHFHLYHU FDQ EH ¿QHDGMXVWHG E\ “ GHJUHHV
<In case of MS-SFB-7-T>
57
Hexagon-socket
head bolt for beam-
axis alignment
15°
15°
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
<In case of MS-SFB-1>
Hexagon-socket
head bolt for beam-
axis alignment
15°
15°

Advertisement