2-5-6 Series Connection
(Wiring Example of the Control Category 4)
[Connectable up to 3 sets of the devices (however, 192 beam channels max.)]
7KLV LV WKH FRQ¿JXUDWLRQ IRU FRQQHFWLQJ PXOWLSOH VHWV RI HPLWWHUV DQG UHFHLYHUV IDFLQJ HDFK RWKHU
in series. It is used when the dangerous part can be entered from two or more directions. If any
of the sets is in light blocked status, the control output (OSSD 1 / 2) turns OFF.
<For PNP output>
Gray cable
Gray cable
with black line
Interlock function
External device monitor function Valid
Auxiliary output
The device output is selected depending on the connecting state of the output polarity setting wire
(shield). Incorrect wiring may cause the lockout state.
* Symbols
Switch S1
9V WR 9V 9 VLQN FXUUHQW P$ RU OHVV (PLVVLRQ KDOW 1RWH 2SHQ (PLVVLRQ
. . ([WHUQDO GHYLFH )RUFHG JXLGHG UHOD\ RU PDJQHWLF FRQWDFWRU
1RWHV 9V LV WKH DSSO\LQJ VXSSO\ YROWDJH
2) The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, gray, gray /
black, sky-blue / white, sky-blue / black, there is no lead wire.
3) For resetting, refer to "3-2 Interlock Function."
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
For series connection, connect the emitter and emitter, receiver and receiver re-
spectively using the exclusive cable (6)%&6/ ) for series connection. Wrong
connection could generate the non-sensing area, resulting in death or serious in-
jury.
(Gray) Interference prevention +
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Yellow) Override input
(Brown) +V
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-bule / White) Muting input A
(Sky-bule / Black) Muting input B
(Gray / Black) Interference prevention -
(Gray) Interference prevention +
Valid (Manual reset)
Can be used
*S1
+
Load
-
K1
K2
K1
K2
24V DC
±10 %
40