2-3-2 Safety Distance

The safety distance is the minimum distance that must be maintained between the device and
the dangerous parts of the machine so that the machine can be stopped before a human body
or an object can reach the dangerous parts.
The safety distance is calculated based on the equation described in the next page when a per-
son moves perpendicular (normal intrusion) to the sensing area of the device.
Dangerous
part
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
Calculate the safety distance correctly, and always maintain the distance which
is equal to or greater than the safety distance, between the sensing area of this
device and the dangerous parts of the machine. If the safety distance is miscal-
FXODWHG RU LI VXI¿FLHQW GLVWDQFH LV QRW PDLQWDLQHG WKH PDFKLQH ZLOO QRW VWRS TXLFNO\
before reaching to the dangerous parts, which can result in death or serious injury.
Before designing the system, refer to the relevant standards of the region where
this device is to be used, and then install this device.
Furthermore, the equation described in the next pages is to be used only in case
the intrusion direction is perpendicular to the sensing area. In case the intrusion
direction is not perpendicular to the sensing area, be sure to refer to the relevant
VWDQGDUG UHJLRQDO VWDQGDUG VSHFL¿FDWLRQ RI WKH PDFKLQH HWF IRU GHWDLOV RI WKH
calculation.
The max. response time of the machine is from the point that the machine re-
ceives the halt signal from this device to the point that the dangerous parts of the
machine stops. The max. response time of the machine should be timed with the
machine to be actually used.
The size of the minimum sensing object for this device varies depending on the
FDVH ZKHWKHU WKH ÀRDWLQJ EODQNLQJ IXQFWLRQ LV DSSOLHG RU QRW &DOFXODWH WKH VDIHW\
distance with the proper size of the minimum sensing object and appropriate
equation.
6L]H RI PLQLPXP VHQVLQJ REMHFW ZKHQ DSSO\LQJ ÀRDWLQJ EODQNLQJ IXQFWLRQ!
SF4B-F <V2>
(10mm-beam channel pitch type)
SF4B-H <V2>
(20mm-beam channel pitch type)
SF4B-A <V2>
(40mm-beam channel pitch type)
1RWH 5HIHU WR ³3-9 Functions Using Handy Controller (SFB-HC) (Optional)" for details of
WKH ÀRDWLQJ EODQNLQJ IXQFWLRQ
Safety distance S
Floating blanking function
Invalid
1 beam
channel
ø14mm
ø24mm
ø25mm
ø45mm
ø45mm
ø85mm
Sensing area
Intrusion direction
Setting (Note)
2 beam
channels
ø34mm
ø65mm
ø125mm
ø165mm
3 beam
channels
ø44mm
ø85mm
14