[For use in the United States of America (as per ANSI B11.19)]
Equation 2
Ds
 6DIHW\ GLVWDQFH PP
Minimum required distance between the sensing area surface and the danger-
ous parts of the machine
.
 ,QWUXVLRQ VSHHG ^5HFRPPHQGHG YDOXH LQ 26+$ LV  LQFKVHF >§  PPVHF @ `
$16, % GRHV QRW GH¿QH WKH LQWUXVLRQ VSHHG ³.´ :KHQ GHWHUPLQLQJ . FRQ-
sider possible factors including physical ability of operators.
7V
 Halting time calculated from the operation time of the control element (air valve, etc.) (sec.)
7F
 Maximum response time of the control circuit required for functioning the brake (sec.)
T
 5HVSRQVH WLPH RI WKLV GHYLFH VHF
SF4B
T
 $GGLWLRQDO KDOWLQJ WLPH WROHUDQFH IRU WKH EUDNH PRQLWRU VHF
bm
The following equation holds when the machine is equipped with a brake monitor.
T
T
When the machine is not equipped with a brake monitor, it is recommended that
20% or more of (Ts + Tc) is taken as additional halting time.
D
 $GGLWLRQDO GLVWDQFH FDOFXODWHG IURP WKH VL]H RI WKH PLQLPXP VHQVLQJ REMHFW RI
pf
the device (mm)
6)%) 9! Dpf = 23.8mm
6)%+ 9! Dpf = 61.2mm
6)%$ 9! Dpf = 129.2mm
Dpf = 3.4 × (d - 0.276) (inch)
G 0LQLPXP VHQVLQJ REMHFW GLDPHWHU  LQFK §  PP 6)%) 9!
<Reference>
:KHQ WKH ÀRDWLQJ EODQNLQJ IXQFWLRQ LV DSSOLHG WKH PLQLPXP VHQVLQJ REMHFW EHFRPHV ODUJH $FFRUGLQJ WR
$16, % 'SI
PP IW ZKHQ G ! PP  LQFKHV 
<Reference>
Since the calculation above is performed by taking 1 (inch) = 25.4 (mm), there is a slight difference be-
tween the representation in (mm) and that in (inch). Refer to the relevant standard for the details.
<Calculation Example>
Calculation Example 2 For use in the United States of America
>2)) UHVSRQVH WLPH PV RU OHVV PLQLPXP VHQVLQJ REMHFW GLDPHWHU  LQFK §  PP @
Ds
= K × (Ts + Tc + T
= 63 × (Ta + 0.014) + 3.4 × (d - 0.276) (inch)
= 63 × (Ta + 0.014) + 3.4 × (0.552 - 0.276)
= 63 × Ta + 63 x 0.014 + 3.4 × 0.276
= 63 × Ta + 1.8204
§  î 7D   LQFK
In case this device is installed in a system with a maximum halting time 0.1 (sec.)
Ds
= 63 × Ta + 1.82
= 63 × 0.1 + 1.82
= 8.12 (inch)
§  PP
Hence, as per the calculations
<Reference>
Since the calculation above is performed by taking 1 (inch) = 25.4 (mm), there is a slight difference be-
tween the representation in (mm) and that in (inch). Refer to the relevant standard for the details.
17
Ds = K
= Ta - (Ts + Tc)
bm
 6HWWLQJ WLPH RI EUDNH PRQLWRU VHF
a
§  î G   PP
0LQLPXP VHQVLQJ REMHFW GLDPHWHU  LQFK §  PP 6)%+ 9!
0LQLPXP VHQVLQJ REMHFW GLDPHWHU  LQFK §  PP 6)%$ 9!
+
SF4B
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
(Ts + Tc + T
×
SF4B
T
) + D
bm
pf
D
s is 206.2 (mm).
+ T
) + D
bm
pf