X7 - X8 - LinMot C1100 series Installation Manual

Table of Contents

Advertisement

7.4 X4
X4
Logic Supply / IO Connection
DSUB-9 (f)
Inputs (X4.5 ... X4.8):
Outputs (X4.3 & X4.4):
Spring cage
Analog inputs:
connector (has to
X4.9:
be ordered
separately: see
X4.10/X4.11:
chapter 14)
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm
- Stripping length: 10mm
- The 24VDC supply for the control circuit (X4.2) must be protected with an external fuse (3A slow blow)
7.5 X7 – X8
X7 – X8
RS485/CAN (on GP drives only)
RJ-45
Use twisted pair (1-2, 3-6, 4-5, 7-8) cable for wiring.
The built in RS485 and CAN terminations can be activated by S4.2 and S4.3.
X7 is internally connected to X8 (1:1 connection)
Page 12 of 29
11
AnIn-
X4.11
10
AnIn+
X4.10
9
AnIn
X4.9
8
In
X4.8
7
In
X4.7
6
In
X4.6
5
In
X4.5
4
Out
X4.4
3
Out
X4.3
2
+24VDC Supply
1
GND
Supply
24V / 5mA (Low Level: –0.5 to 5VDC, High Level: 15 to 30VDC)
24V / max.500mA, Peak 1.4A (will shut down if exceeded)
10 bit A/D converted
Single ended analog input to GND, 0..10V, Input Resistance: 51kΩ to GND
Differential analog input, +/- 10V. Common mode range: +/- 5VDC to GND,
Input Resistance 11.4kΩ for each signal to GND.
1
RS485_Rx+
2
RS485_Rx-
3
RS485_Tx+
4
NC
5
GND (1k Ohm to GND)
6
RS485_Tx-
7
CAN_H
8
CAN_L
case
Shield
0185-1062-E_6V12_IG_Drives_C1100
Configurable differential analog Input (with X4.10)
Configurable differential analog Input (with X4.11)
Configurable single ended analog Input
Configurable digital Input
Configurable digital Input
Configurable digital Input
Configurable digital Input
Configurable digital Output
Configurable digital Output
Logic Supply 22-26 VDC
Ground
2
A
B
Y
Z