X33; X7 - X8 - LinMot E1450-PL-QN-0S Installation Manual

E14x0 v2 series
Hide thumbs Also See for E1450-PL-QN-0S:
Table of Contents

Advertisement

7.8 X33

X33
Spring cage connector
7.9 X7 – X8

X7 - X8

CMD (RS485/CAN)
RJ-45
Use twisted pair (1-2, 3-6, 4-5, 7-8) cable for wiring.
The built in RS485 and CAN terminations can be activated by S5.2 and S5.3.
X7 is internally connected to X8 (1:1 connection)
7.10 X9
X9
PROFIBUS DP (only available on E1430-DP-QN)
DSUB-9 (f)
Max. Baud rate: 12Mbaud
NTI AG / LinMot
Safety Relays (only with the -1S option)
4 / 8
Ksr +
3 / 7
Ksr -
2 / 6
Ksr f+
1 / 5
Ksr f-
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm 2 (AWG 16)
- Stripping length: 10mm
- Never connect the safety relays to the logic supply of the drive!
1
RS485_Rx+
2
RS485_Rx-
3
RS485_Tx+
4
GND
5
GND
6
RS485_Tx-
7
CAN_H
8
CAN_L
case
Shield
1
Not connected
6
+5V
2
Not connected
7
Not connected
3
RxD/TxD-P
8
RxD/TxD-N
4
CNTR-P
9
Not connected
5
GND
case
Shield
®
www.LinMot.com
E1400 V2 Installation Guide
Safety Relay 1 / 2 Input positive
Safety Relay 1 / 2 Input negative
Safety Relay 1 / 2 feedback positive
Safety Relay 1 / 2 feedback negative
A
B
Y
Z
(isolated)
(isolated)
Page 13/27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents