E1400 V1 Rev. D Installation Guide

6.7 X7 - X8

X7 - X8
CMD (RS485/CAN)
RJ-45
Use twisted pair (1-2, 3-6, 4-5, 7-8) cable for wiring.
The built in RS485 and CAN terminations can be activated by S5.2 and S5.3.
X7 is internally connected to X8 (1:1 connection)
6.8 X9
X9
PROFIBUS DP (only available on E1430-DP-QN)
1
2
3
4
5
DSUB-9 (f)
Max. Baud rate: 12Mbaud
Page 12/24
1
RS485_Rx+
A
2
RS485_Rx-
B
X3
RS485_Tx+
Y
4
GND
5
GND
6
RS485_Tx-
Z
7
CAN_H
8
CAN_L
case
Shield
Not connected
6
+5V
(isolated)
Not connected
7
Not connected
RxD/TxD-P
8
RxD/TxD-N
CNTR-P
9
Not connected
GND
(isolated)
case
Shield
www.LinMot.com
®