X33; X7 - X8 - LinMot E14 0 V1 Series Installation Manual

Rev. e and rev. f servo drives
Hide thumbs Also See for E14 0 V1 Series:
Table of Contents

Advertisement

E1400 V1 Rev. E Installation Guide

6.8 X33

X33
Spring cage connector

6.9 X7 - X8

X7 - X8
CMD (RS485/CAN)
RJ-45
Use twisted pair (1-2, 3-6, 4-5, 7-8) cable for wiring.
The built in RS485 and CAN terminations can be activated by S5.2 and S5.3.
X7 is internally connected to X8 (1:1 connection)
6.10
X9
X9
PROFIBUS DP (only available on E1430-DP-QN)
1
2
3
4
5
DSUB-9 (f)
Max. Baud rate: 12Mbaud
Page 12/23
Safety Relays (only with the -1S option)
4 / 8
Ksr +
3 / 7
Ksr -
2 / 6
Ksr f+
1 / 5
Ksr f-
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm
- Stripping length: 10mm
- Never connect the safety relays to the logic supply of the drive!
1
RS485_Rx+
2
RS485_Rx-
X3
RS485_Tx+
4
GND
5
GND
6
RS485_Tx-
7
CAN_H
8
CAN_L
case
Shield
Not connected
6
+5V
Not connected
7
Not connected
RxD/TxD-P
8
RxD/TxD-N
CNTR-P
9
Not connected
GND
case
Shield
www.LinMot.com
Safety Relay 1 / 2 Input positive
Safety Relay 1 / 2 Input negative
Safety Relay 1 / 2 feedback positive
Safety Relay 1 / 2 feedback negative
2
A
B
Y
Z
(isolated)
(isolated)
®
NTI AG / LinMot

Advertisement

Table of Contents
loading

Table of Contents