Click on the Light and Imager Settings hotkey in the System menu (Fig. 61). This will open the Light
and Imager Settings dialog. In this dialog you can change trigger settings on the Trigger tab,
exposure and gain settings on the Imager Settings tab and control illumination on the Light Settings
tab. Select the Trigger Settings tab if it is not selected by default. In the Trigger Type droplist select
Burst (external), a Burst Length of five and an Interval of 500000 µs (one half second) (Fig.
62). With these settings, when the system is triggered it will take a maximum of five images with a
period of one half second between images. If a code is read before the image count reaches five,
the reader will stop triggering.
Fig. 61 - Light and Imager Settings Hotkey
Fig. 62 - Light and Imager Settings Dialog
37