Technology summit 2017, dataman id basic and advanced labs

Advertisement

Buffering and Transferring Images
Introduction:
When you are setting up a new system or troubleshooting an existing one, it is often helpful to save
images of codes that have been read and those that were not read. These can help to better
understand what is causing problems and what works well within your process. The DataMan Setup
Tool offers a convenient way to save images to your computer while your computer is
connected to the system. In this lab you will investigate the Buffering & Transfer menu.
Start:
So that whatever settings you have changed to this point do not affect what you want to accomplish
in this lab you need to reset the configuration to a default state. To do this click on the System menu
in the ribbon and then click on the Reset Configuration hotkey (Fig. 59). Confirm that you want to
reset the configuration when prompted. The reset will take a couple of seconds to complete.
Fig. 59 - Reset Configuration
When the reset is finished place the Ace of Clubs in the field of view using the aimer LED's for
positioning. From the Tune menu of the Quick Setup pane click on both the Optimize Brightness
and the Optimize Focus buttons on the left side of the tune menu. Trigger the reader to read the
code; you should see something like the image below (Fig. 60).
Fig, 60 - Ace Of Clubs