Fig. 48 - Standard Formatting Universal Tab
On the General tab under Data is a list of predefined values and delimiters. To create a formatted
string, select the desired value from the list by clicking on it and then click the Add button. For this
lab select <Full string> click Add; scroll down to find <SP> (for space) click it and then click Add;
scroll down and find <Used Read Setup> click it and then click Add. This will create the string
shown in the above image (red oval in Fig. 48).
Return to the Quick Setup pane and place the Ace of Hearts in the field of view at table top height
and trigger the reader. Place the Two of Diamonds in the field of view at the same height as when it
was tuned (two to three inches from the front of the reader) and trigger the reader. Place the Ace of
Diamonds in the field of view at the table top height (same as Ace of Hearts) and trigger the
reader. Each code should be read and in the Result History pane you should see something like the
image below (Fig. 49). Next to each string is the number of the setup that was used to read the
code.
Fig. 49 - Read Setups Result History