Chapter 7 : REMOTE CONTROL PROGRAMMER'S GUIDE (continued)
7-4. COMMANDS AND RESPONSES TABLE (continued)
ASCII
RESPONSE
COMMAND
IMAGE COMMANDS
yC
ACAD
H
HP
V
VP
W
HW
S
VS
B
BRG
D
CON
O
COL
T
HUE
QP
PRO
QO
OVR
A
ASP
QR
RLV
QG
GLV
QB
BLV
MC
CLK
MP
PHA
yP
PRES
yc
acad
h
hp
v
vp
w
hw
s
vs
b
brg
d
con
o
col
t
hue
qp
pro
qo
ovr
a
asp
qr
rlv
qg
glv
qb
blv
mc
clk
mp
pha
yp
pres
yS
STO
NOTE:
PAGE 44
COMMAND
DESCRIPTION
Automatic centering (M).
Horizontal position (M).
Vertical position (M).
Horizontal size (M).
Vertical size (M).
Brightness adjustment (M).
Contrast adjustment (M).
Color adjustment (M).
Hue adjustment (M).
Sharpness adjustment (M).
Underscan / overscan (M)
Input aspect ratio selection (M)
Red level adjustment (M)
Green level adjustment (M)
Bleu level adjustment (M)
Number of pixels per line (M)
Pixels phase adjustment (M)
PRESET (M).
Automatic centering (P).
Horizontal position (P).
Vertical position (P).
Horizontal size (P).
Vertical size (P).
Brightness adjustment (P).
Contrast adjustment (P).
Color adjustment (P).
Hue adjustment (P).
Image process adjustment (P)
Underscan / overscan (P)
Input aspect ratio selection (P)
Red level adjustment (P)
Green level adjustment (P)
Bleu level adjustment (P)
Number of pixels per line (P)
Pixels phase adjustment (P)
PRESET (P).
STORE.
(M) = output 1.
(P) = output 2.
TYPE
MIN MAX
Rd/Wr
0
1
1 = centering action (automatic reset).
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
7
0 = level 1...................... 7 = level 8.
Rd/Wr
0
1
0 = underscan
Rd/Wr
0
2
0 = 4/3
2 = 16/9 anamorphic
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
65535
Rd/Wr
0
31
Rd/Wr
0
1
1 = PRESET action (automatic reset).
Rd/Wr
0
1
1 = centering action (automatic reset).
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
7
0 = level 1...................... 7 = level 8.
Rd/Wr
0
1
0 = underscan
Rd/Wr
0
2
0 = 4/3
2 = 16/9 anamorphic
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
65535
Rd/Wr
0
31
Rd/Wr
0
1
1 = PRESET action (automatic reset).
Rd/Wr
0
1
1 = STORE action (automatic reset).
Rd/Wr = Read and write command.
Rd = Read only command.
NATIX™
VALUE
DESCRIPTION
1 = overscan
1 = letterbox
3 = zoom.
1 = overscan
1 = letterbox
3 = zoom.