Machine description – quick overview
Description
0
Gas post-flow time (TIG)
Setting ranges: 0.00 sec to 40.0 sec (0.1 sec increments).
Balance
TIG kHz-pulsing (metallurgical pulsing)
Setting range: 1% to +99% (increments of 1%)
MMA pulse welding
Setting range: 1% to +99% (increments of 1%)
Frequency
TIG kHz-pulsing (metallurgical pulsing)
Setting range: 0.05 kHz to 15 kHz
MMA pulse welding
Setting range: 0.2 Hz to 500 Hz
activArc TIG welding process
Switch activArc on or off
Correct the activArc characteristic (setting range: 0 to 100)