Specifications And Requirements; Specifications-Reader - Banner ABR 3000 Series Instruction Manual

Hide thumbs Also See for ABR 3000 Series:
Table of Contents

Advertisement

ABR 3000 Series Barcode Reader

2 Specifications and Requirements

2.1 Specifications—Reader
Supply Voltage
5 V dc to 30 V dc
10 V dc to 30 V dc with TCNM-ACBB1
Consumption
0.4 A maximum at 5 V dc
0.1 A maximum at 30 V dc
Communication Interface
Main RS232 or RS422 full duplex: 2400 bit/s to 115200 bit/s
USB: USB 2.0 Hi-Speed
2
Ethernet
: 10/100 Mbit/s
Inputs
Input 1 (External Trigger) and Input 2: Protected against short-circuits
(opto-isolated, polarity insensitive, and PNP only when connected
Inputs
through TCNM-ACBB1, see
Maximum voltage: 30 V dc
Maximum input current: 3.5 mA
Outputs
2 NPN/PNP/Push-Pull software selectable, reverse polarity and short
circuit protected outputs available (2 Opto-isolated outputs instead if
Outputs
using TCNM-ACBB1, see
Maximum Current: 100 mA maximum continuous or 145 mA pulsed
Output Saturation Voltage (in PNP or NPN mode): < 1.7 V at 100 mA
Maximum load device voltage drop (in NPN mode): 30 V
Optical Features
Image Sensor: CMOS sensor with Global Shutter
WVGA
Image Format
752 × 480
Frame Rate
57 frames/second
3
Focus Range
45 - 70 - 125
Factory calibrated
positions (mm)
Tilt: 0° to 360° within vertical FOV
LED Safety: LED emission according to EN 62471
Laser Safety (Aiming source): IEC60825-1 2007
Lighting System: Internal Illuminator
Aiming System: Laser Indicator
Indicators
Power LED
Ready, Good, Trigger, Com, Status LED
Ethernet Network LED
Green Spot LED
Other
Smart Teach button (configurable via Barcode Manager), beeper
2 The Ethernet interface supports application protocols: TCP/IP, EtherNet/lP, Modbus TCP
3 Three factory calibrated positions; continuous focus range for fine tuning
4 High ambient temperature applications should use metal mounting bracket for heat dissipation.
6
on page 22 for specifications)
on page 25 for specifications)
1.2 MP
1280 × 960
36 frames/second
45 - 80 - 125
www.bannerengineering.com - Tel: + 1 888 373 6767
Construction
Aluminum
Weight in grams (ounces)
Serial and USB: 117 (4.1) with cable
Serial and Ethernet: 200 (7.1) with cable
Operating Conditions
Operating Temperature: 0 °C to +45 °C (+32 °F to +113 °F)
Storage Temperature: –20 °C to +70 °C (–4 °F to +158 °F)
90% maximum relative humidity (non-condensing)
Vibration Resistance EN 60068-2-6
14 mm at 2 to 10 Hz; 1.5 mm at 13 to 55 Hz; 2 a (a), 70 to 500 Hz; 2
hours on each axis
Shock Resistance EN 60068-2-27
30 g; 11 ms; 3 shocks up and 3 down on each axis
Bump Resistance EN 60068-2-29
30g; 6 ms; 5000 bumps up and 5000 down on each axis
Environmental Rating
IEC IP65
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
22
24
26
28
30
Certifications
www.bannerengineering.com
.
5.0
3.0
2.0
1.0
0.8
0.5