8.1.3 Industrial Ethernet Reading Phase Acquisition Control

To acquire individual images using an Industrial Protocol Input Bit, use the following instructions:
1. Go to Reading Phase >
The External Trigger Source list displays.
2. Select an Industrial Protocol Input Bit.
In this example, select Bit 6.
Because the selected bit polarity is set to Leading, the ABR will take an image each time the input bit goes high.

8.1.4 Industrial Ethernet Digital Output Control

The Industrial Ethernet host controller can also drive the ABR reader's physical discrete outputs by assigning individual
communication bits to the Digital Output Activation and Deactivation parameters. These bits are received by the ABR as
Input Bits.
1. Go to Output Setup > Output.
2. Under Activation, select an input bit, leaving the polarity setting as Leading.
In this example, select Input Bit 0.
50
Phase Mode > Acquisition Trigger and select Trigger Type as External.
Figure 61. Industrial Ethernet Strings and Bits
www.bannerengineering.com - Tel: + 1 888 373 6767
Industrial Ethernet Bits