Discard After Read—After the last code in the output buffer is read by the EtherNet/IP server manager (host), it is
deleted from the output buffer. In this way it will not be re-read by the same host (or any host) in case of a re-
connection.
When there is more than one code in the output buffer, the EtherNet/IP protocol requires that each code read by the host
be deleted and replaced by the next code in the output buffer.
8.2.3 ABR Series EDS File Installation in Studio 5000 Logix Designer
Software
Use the EDS Hardware Installation Tool to register the Electronic Data Sheet (EDS) file.
Use the follow the steps, as well as
quickly and easily establish an implicit Class 1 connection between the ABR and a Rockwell Studio 5000 Logix Designer
family PLC. Screenshots are from an example configuration with a ControlLogix 1756-L71 with a 1756-ENBT/A Ethernet
module, using Studio 5000 Logix Designer version 30.
1. Download Banner_ABR_1_1_08312018.eds from
2. On the Tools menu, click EDS Hardware Installation Tool.
The Rockwell Automation's EDS Wizard dialog displays.
3. Click Next.
4. Select Register an EDS file(s).
ABR Series Manual Installation in Studio 5000 Logix Designer Software
www.bannergineering.com
Figure 66. Tools—EDS Hardware Installation Tool
Figure 67. Rockwell Automation's EDS Wizard—Options
www.bannerengineering.com - Tel: + 1 888 373 6767
ABR 3000 Series Barcode Reader
on page 62 to
.
57