Pc Requirements-Barcode Manager - Banner ABR 3000 series Quick Start Manual

Hide thumbs Also See for ABR 3000 series:
Table of Contents

Advertisement

ABR 3000
9. Close the Automatic Setup window.
Your reader is now optimized for decoding. Continue setting up the reader for your application as desired. Typically, Reading Phase is
configured next.
Specifications—Reader
Supply Voltage
5 V dc to 30 V dc
10 V dc to 30 V dc with TCNM-ACBB1
Consumption
0.4 A to 0.1 A maximum
Communication Interface
Main RS232 or RS422 full duplex: 2400 bit/s to 115200 bit/s
USB: USB 2.0 Hi-Speed
10
Ethernet
: 10/100 Mbit/s
Inputs
Input 1 (External Trigger) and Input 2: Protected against short-circuits (opto-isola-
ted and polarity insensitive when connected through TCNM-ACBB1)
Outputs
2 NPN or PNP short circuit protected (opto-isolated and polarity sensitive when
connected through TCNM-ACBB1)
Optical Features
See the Instruction Manual for details
LED Safety: LED emission according to EN 62471
Imager
WVGA: 752 × 480 pixels, CMOS
1.2MP: 1280 × 960 pixels, CMOS
Construction
Aluminum
Operating Conditions
11
Operating Temperature
: 0 °C to +45 °C (+32 °F to +113 °F)
Storage Temperature: –20 °C to +70 °C (–4 °F to +158 °F)
90% maximum relative humidity (non-condensing)
Environmental Rating
IEC IP65
Other
Smart Teach button (configurable via Barcode Manager), beeper
Parameter Storage
Permanent memory (Flash)
Barcode Types
1-D and stacked
PDF417 Standard and Mi-
cro PDF417
Code 128 (GS1-128)
Code 39 (Standard and Full
ASCII)
Code 32
MSI
Standard 2 of 5
Matrix 2 of 5
FCC Statement
Modifications or changes to this equipment without the expressed written approval of Banner Engineering could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
PC Requirements—Barcode Manager
Administrative rights are required to install the Barcode Manager software.
Operating System
Microsoft
®
Windows
®
operating system version XP SP3
Barcode Manager does not currently support Windows Embedded (often used in
industrial PCs and/or PLCs)
System Type
32-bit or 64-bit
Hard Drive Space
2 GB hard disk for 64-bit machines; 1 GB hard disk for 32-bit machines
Memory (RAM)
1 GB RAM
10
The Ethernet interface supports application protocols: TCP/IP, EtherNet/lP, Modbus TCP
11
High ambient temperature applications should use a metal mounting bracket for heat dissipation.
12
Windows XP is not compatible with ABR 3000 USB models.
13
Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries.
P/N 207636 Rev. A
Interleaved 2 of 5
Codabar
Code 93
Pharmacode
EAN-8/13-UPC-A/E (includ-
ing Addon 2 and Addon 5)
GS1 DataBar Family
Composite Symbologies
12
13
, 7, 8, or 10
www.bannerengineering.com - Tel: +1-763-544-3164
Required Overcurrent Protection
WARNING: Electrical connections must be made by
qualified personnel in accordance with local and na-
tional electrical codes and regulations.
Overcurrent protection is required to be provided by end product application per
the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limit-
ing, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
Supply Wiring (AWG)
20
22
24
26
28
30
Certifications
2-D
Data Matrix ECC 200
(Standard, GS1 and Direct
Marking)
QR Code
(Standard and Direct Mark-
ing)
Micro QR Code
MAXICODE
Aztec Code
Processor
2.00 GHz or faster microprocessor
Screen Resolution
One 19-inch or larger monitor, optimized for 1280×1024 resolution
Third-Party Software
Web Browser: Google Chrome, Mozilla Firefox, Microsoft Internet Explorer, Opera,
etc.
Connection
100 Base-T Ethernet
www.bannerengineering.com
.
Required Overcurrent Protection (Amps)
5.0
3.0
2.0
1.0
0.8
0.5
POSTAL
Australia Post
Royal Mail 4 State Custom-
er
Kix Code
Japan Post
PLANET
POSTNET
POSTNET (+BB)
Intelligent Mail
Swedish Post
7

Advertisement

Table of Contents
loading

Table of Contents