388
Definition
11
This log indicates that database reading from flash at Power on
failed. This can be caused by corrupted flash. As a result, the
system starts with the default configuration.
CRITICAL
MMI
RLC, 9150, 911x
None
1) Reconfigure the system and then save it to Flash.
Note:
When you save configuration changes to Flash, the system
suspends new call processing for approximately 30 seconds.
2) Restart the system and log into the system and check the
configured parameters. If the problem persists contact your
vendor.
Reason reading from Flash failed.
Database reading from Flash failed - P1
12
This log indicates that user tried saving a new configuration to
Flash.
NORMAL
MMI
RLC, 9150, 911x
None
None
Status of Save to Flash – success or failure
Database save to Flash: P1