Action
Step 6
a
Make sure the MPF gearbox is free of debris.
b
Check the gears and spring of the MPF gearbox for wear or
damage.
Are they free of damage?
Step 7
Does the error remain?

Understanding the printer messages

Cartridge, imaging unit mismatch [41.xy]

1
Check if the toner cartridge and imaging unit are both MICR or non-MICR supplies.
2
Change the toner cartridge or imaging unit so that both are MICR or non‑MICR supplies.
Notes:
Use a MICR toner cartridge and imaging unit for printing checks and other similar documents.
Use a non-MICR toner cartridge and imaging unit for regular print jobs.

Cartridge low [88.xx]

You may need to order a toner cartridge. If necessary, press
printing.

Cartridge nearly low [88.xy]

Press
on the printer control panel, if necessary, to continue printing.

Cartridge very low [88.xy]

You may need to replace the toner cartridge very soon. If necessary, press
to continue printing.

Non-Lexmark cartridge, see User's Guide [33.xy]

The printer has detected a non‑Lexmark supply or part installed in the printer.
Your Lexmark printer is designed to function best with genuine Lexmark supplies and parts. Use of third-
party supplies or parts may affect the performance, reliability, or life of the printer and its imaging
components.
Diagnostics and troubleshooting
108
Yes
No
Go to step 7.
Replace the MPF
gearbox. See
gearbox removal"
on page
Contact the next
The problem is
level of support.
solved.
on the printer control panel to continue
on the printer control panel
4514-2xx
"MPF
200.