Enter between 2 and 30 input and output values as percentages.
Menu item
1.1.10.4.3
1.1.10.4.4
1.1.10.4.5
...
1.1.10.4.61
1.1.10.4.62
"1.1.11 User"
Note
This menu command is visible only if "user" has been selected under "1.1.2 PV Select"
(Page 69).
See also
"User" measurement type (Page 153)
"1.1.11.1 User Curve Unit"
Factory setting:
Setting range:
Purpose:
Description:
"1.1.11.2 User LRV"
Factory setting:
Adjustment range:
Purpose:
Description:
SITRANS P500 with HART
Operating Instructions, 12/2014, A5E02344528-09
Designation
X0
Y0
X1
...
X29
Y29
AAAAA
5 characters
Enter a user-specific unit
This parameter allows you to set the unit of the user-specific measured
variable. The parameters associated with this unit are automatically con-
verted into the new unit.
The user-specific unit consists of up to 5 characters, freely selectable.
0
Freely selectable numeric value
Setting the start of scale value
This parameter allows the start of scale value for the user scaling to be set.
The value that is set for "1.1.3.1.2 Setting LRV" (Page 69) or "1.1.3.2.2 Set
LRV with Pressure" (Page 70) is automatically assigned to this value.
The start of scale value is expressed in the units you selected under
"1.1.11.1 User Curve Unit" (Page 81).
Operate
6.2 Parameter description
81