TROUBLE
CAUSE
1. Button does not work
2. Wiring connections are not in good
condition
Motor
does not
3. Motor burned out
run
4. Height Limit Switch is damaged
5. AC contactor burned out
1. Motor runs in reverse rotation
2. Gear Pump out of operation
Motor runs
but the
3. Release Valve in damage
lift is not
4. Relief Valve or Check Valve in
raised
damage
5. Low oil level
1. Release Valve out of work
Lift does
not stay
2. Relief Valve or Check Valve leakage
up
3. Cylinder or Fittings leaks
1. Oil line is jammed
2. Motor running on low voltage
Lift raises
3. Oil mixed with air
slowly
4. Gear Pump leaks
5. Overload lifting
1. Safety device are in activated
2. Release Valve in damage
Lift will
not lower
3. Safety cable broken
4. Oil system is jammed

Trouble Shooting

Trouble Shooting
PV-10PX / PV-10HPX
REMEDY
1. Replace button
2.Repair all wiring
connections
3. Repair or replace motor
4.Replace the Limit Switch
5. Replace AC Contactor
1.Reverse two power wire
2.Repair or replace
3. Repair or replace
4.Repair or replace
5.Fill tank
Repair or replace
1. Clean the oil line
2. Check Electrical System
3. Fill tank
4. Replace Pump
5. Check load
1. Release the safeties
2. Repair or replace
3. Replace
4. Clean the oil system