Siemens ERTEC200 Manual page 42

Enhanced real-time ethernet controller
Table of Contents

Advertisement

RELD_PREDIV
Description
Reload register for the two prescalers
Bit No.
Name
7:0
Prediv [7:0]
15:8
Prediv [15:8]
31-16
Reserved
TIM0
TIM1
Description
Timer Register 0-1. Values of timers 0-1.
Bit No.
Name
31:0
Timer [31:0]
TIM2_CTRL
Description
Timer 2 Control Register
Bit No.
Name
31:19
Reserved
18
Timer_Mode
17
OneShot_Mode
16
Run/xStop
15:0
Reload [15:0]
TIM2
Description
Timer Register 2. Values of Timer 2.
Bit No.
Name
31:16
Reserved
15:0
Timer [15:0]
Copyright © Siemens AG 2007. All rights reserved.
Technical data subject to change
R/W
Addr.: 0x4000_2014
Description
Reload value of prescaler 0
Reload value of prescaler 1
Not relevant (read=0)
R
Addr.: 0x4000_2018
R
Addr.: 0x4000_201C
Description
Current value of the timer
R/W
Addr.: 0x4000_2020
Description
Reserved
0: Cyclic
1: Retrigger via UART_RXD signal (for RXD at log. '0')
0: Cycle timer: Timer 2 is loaded with 0000h when timer value = reload value
and continues to run
1: OneShot-Timer: Timer 2 stops when timer value = reload value
0: Stop Timer 2, reset Timer 2, deactivate INT
1: Start Timer 2
Reload value of Timers 2
R
Addr.: 0x4000_2024
Description
Reserved
Current value of Timer 2
42
Default: 0x0000_0000
Default: 0x0000_0000
Default: 0x0000_0000
Default: 0x0000_0000
Default: 0x0000_0000
ERTEC 200 Manual
Version 1.1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents