Initial Panel Programming - DSC TL280 Installation Manual

Internet alarm communicator - international
Hide thumbs Also See for TL280:
Table of Contents

Advertisement

Install Network Cable
1. Route the CAT 5 Ethernet cable through back of the panel and plug it into the communicator's RJ45 jack.
2. Perform the following steps for initial power on of the panel with communicator installed:
a. Reconnect the AC power, telephone line, and battery + connector to the panel.
(The communicator and panel will power up together).
b. Observe that the communicator's red and yellow LEDs are flashing together while it initializes. The red and yellow
LEDs will continue to flash until the communicator has successfully communicated to all programmed receivers. If this
is the first time the communicator has been powered up, the module will not be able to initiate communication until it
has been programmed.
NOTE: Initialization may take several minutes to complete. Red and yellow LEDs will flash together during initialization. Do not
continue to next step until the red and yellow LEDs have stopped flashing. (If only the yellow LED is flashing, there is a
communicator trouble). Correct trouble indicated by flashes on yellow LED before continuing. (for troubleshooting
assistance see Table 6 ).
3. Mount the panel in location.
Keypad Data Display
NOTE: Programming locations are accessible via the keypad.
Section-Toggle Options: The number is displayed when toggle is ON, the number is not displayed when toggle is OFF.
l
(e.g., toggle options displays: [--3--6--]. Options 3 and 6 are ON, all others are OFF). Pressing keys 1 through 8 will altern-
ately turn the toggle ON and OFF.
HEX/Decimal Data: Values that are provided with two defaults, separated by a "/" character, use the format: hexadecimal
l
followed by decimal equivalent (e.g., default [0BF5/3061]). Hexadecimal numbers are shown, with all leading zeros, to the
full field length defined for the number.
Entering HEX values at keypad
To enter HEX values at the keypad, press the * key before entering the HEX value. (e.g., to enter "C" at the keypad, press [*][3])
Entering ASCII Characters at keypad
1. Press [*] and use scroll buttons [<] [>] to display "ASCII Entry" on the LCD screen.
2. Press [*] to select ASCII entry mode.
3. Use the [<] [>] scroll keys to display the desired character and press [*] to save and exit ASCII.
4. Repeat the steps above to enter another ASCII character.
HS2016/2032/2064/2128 Initial Programming
Please refer to the panel manual for details. Perform the following steps to ensure that the communicator and the panel work
together as intended. These sections must be programmed at the panel keypad. Enter [*][8][Installer Code][Section Number].
Record any values that are modified from their default, in the appropriate worksheets for the panel or communicator.
1. In panel section [377] 'Communication Variables', subsection [002] 'Communication Delays', sub-subsection [1] 'Com-
munication Delay', program 060 (seconds).
2. In panel section [382] 'Communicator Option 3' set option [5] ON.
NOTE: If this option is OFF, the yellow status LED on the communicator will indicate 'Panel Supervision Trouble' (2 flashes)
and the unit can not be programmed via the PC-LINK cable.
NOTE: Account number in communicator section [851 ][021] automatically syncs with panel system account number in section
[310][000] 'Account Code'.
3. In panel sections [300] subsections [001] to [004], program the subsection with 02 to 06.
Table 3: RS-232 Connections
3rd Party Device Communicator
TX
RX+
Unused
RX-
RX
TX+
Unused
TX-
GND
GND

Initial Panel Programming

8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl280r

Table of Contents