DSC TL280 Installation Manual page 23

Internet alarm communicator - international
Hide thumbs Also See for TL280:
Table of Contents

Advertisement

[097] SA Call Up IP
Default (000.000.000.000)
[098] SA Call Up Port
Default (0000) Valid range: 0000 - FFFF.
[099] SA Password
Default (FFFFFFFF) Valid range: 00000000 - FFFFFFFF.
Ethernet Receiver 1 Options
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
Valid range: 0000000001 - FFFFFFFFFE.
[102] Ethernet Receiver 1 DNIS
Default (000000) Valid range: 000000 - FFFFFF.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
[104] Ethernet Receiver 1 UDP Remote Port
Default (0BF5/3061) Valid range: 0000 - FFFF.
[105] Ethernet Receiver 1 UDP Local Port
Default (0BF4/3060)Valid range: 0000 - FFFF.
[106] Ethernet Receiver 1 Domain Name
Default ( ) 32 ASCII characters.
________________________________
Ethernet Receiver 2 Options
[111] Ethernet Receiver 2 Account Code
Default (0000000000)
Valid range: 0000000001 - FFFFFFFFFE.
[112] Ethernet Receiver 2 DNIS
Default (000000) Valid range: 000000 - 0FFFFF.
[113] Ethernet Receiver 2 Address
Default (000.000.000.000)
[114] Ethernet Receiver 2 UDP Remote Port
Default (0BF5/3061) Valid range: 0000 - FFFF.
[115] Ethernet Receiver 2 UDP Local Port
Default (0BF9/3065) Valid range: 0000 -FFFF.
[116] Ethernet Receiver 2 Domain Name
Default ( )
____________________________________
Ethernet Options
[124] Ethernet Test Transmission Time
Default (9999) Valid: 00-23(HH); 00-59(MM)
[125] Ethernet Test Transmission Cycle
Default (000000)
Valid range: 000000 - 999999 minutes.
[226] Network Trouble Delay
Default (0F)
Valid entries from, 00 to FF.
[651] Integration Identification Number
Default ()
[652] Integration Access Code
Default ()
[663] Integration Toggle Options 2
[1] Integration Over Serial Port (ON)
[2] Reserved
[3] Integration Over Ethernet (OFF)
[4] Reserved
[5] Integration Protocol (ON)
[6] Reserved
[7] Reserved
[8] Reserved
[664] Integration Toggle Options 3
[1] UDP Polling (OFF)
[2] TCP Polling (OFF)
[3] Real-time Notification (OFF)
[4] Notification Follows Pool (OFF)
[5] Reserved
[6] Reserved
[7] Reserved
[8] Reserved
[665] Integrated Poll Interval in Seconds
Default (000A) Valid range: 0000 - FFFF.
[693] Integration Server IP
Default (000.000.000.000).
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl280r

Table of Contents