NOTE: If no value is programmed and DHCP is used, the DHCP server will assign this value. If an address is programmed and
DHCP is used, the programmed address will be used instead of the DHCP address.
Programming Options
[010] System Toggle Options 3
[1] Reserved.
[2] Visual verification. Default (OFF)
ON: Visual verification is enabled.
OFF: Visual verification is disabled.
[3]-[8] Reserved.
[011] Installer Code
Default (CAFE)
Program the installer code for the communicator module. The installer code will be required when programming the com-
municator module. Valid range: 0000 - FFFF.
[012] DLS Incoming Port
Default (0BF6/3062)
The DLS incoming local port (listening port) is the port DLS V will use when connecting to the communicator. If a router or gate-
way is used, it must be programmed with a transmission control protocol (TCP) port forward for this port to the communicator
module IP address. Valid range: 0000 - FFFF.
[013] DLS Outgoing Port
Default (0BFA/3066)
The DLS outgoing port is used for outgoing session to DLS V after an SMS request has been sent to the communicator. Use
this section to set the value of the local outgoing port. The value must be changed if the communicator is located behind a fire-
wall and must be assigned a particular port number, as determined by the network administrator. In most cases, changing the
default value or configuring the firewall with this port is not required.
Valid range: 0000-FFFF.
NOTE: If section [006] toggle option [7] is ON, DLS will use the primary path for session. If section [006] toggle option [7] is OFF
DLS will use the Ethernet path, if available.
[015] DLS Call-Up IP
Default (000.000.000.000)
[016] DLS Call-Up Port
Default (0000)
[020] Time Zone
Default (00)
Please refer to panel manual section 'Real Time Clock' for more details. Use Column 2 (Offset Hours) to find the local Time
Zone. Record the two digit HEX value from Column 1 (HEX Value) on the same row. Program this HEX value for the Time
Zone. Valid range is 00 - FF.
HEX
Value
01
05
09
0B
0D
11
15
19
1D
1F
21
23
Table 7: World Wide Time Zones
Offset
Standard
Hours
Abbreviation
-12
BIT
-11
SST
-10
HAST
-9.5
MIT
-9
AKST
-8
PST
-7
MST
-6
CST
-5
EST
-4.5
VST
-4
AST
-3.5
NST
Location
Baker Island Time
Somoa Standard Time
Hawaii-Aleutian Standard Time
Marquesas Island Time
Alaska Standard Time
Pacific Standard Time
Mountain Standard Time
Central Standard Time
Eastern Standard Time
Venezuela Standard Time
Atlantic Standard Time
Newfoundland Standard Time
13