[226] Network Trouble Delay
Default (0F)
This option is used to program the delay, in minutes, for reporting/displaying a network trouble. Valid entries are 00 - FF (e.g.,
for a 10 minute network trouble delay enter: 0A). When this Timer is programmed as 00, Ethernet and Supervision troubles are
not communicated or displayed on the keypad.
[651] Integration Account Code
This section will display the unique 12-digit number assigned to this communicator for the identification when integrated with
third party applications.
[652] Integration Access code
This section is a programmable 8 digit number used for initialization with third party applications.
[663] Integration Toggle Option 2
This toggle options in this section are used to enable and configure the path used for integration with third party applications.
NOTE: Only one integration path can be enabled at a time .
[1] Integration Over Serial Toggle Default (ON)
ON: Integration over serial enabled.
OFF: Integration over serial disabled.
[2] Reserved.
[3] Integration Over Ethernet Toggle Default (OFF)
ON: Integration over Ethernet enabled.
OFF: Integration over Ethernet disabled.
[4] Reserved.
[5] Integration Protocol Default (ON)
ON: Integration protocol enabled.
OFF: Integration protocol disabled.
[6]-[8] Reserved
[664] Integration Toggle Option 3
The toggle options in this section are used to determine the polling and notification behavior used for integration with third
party applications.
[1] UDP Polling Default (OFF)
[2] TCP Polling Default (OFF)
[3] Real-time Notification Default (OFF)
[4] Notification Follows Poll Default (OFF)
[5]-[8] Reserved.
[665] Integration Polling Interval in Seconds
(Default: 000A)
This option controls the polling interval from the alarm panel to the integration interface for the purpose of optimizing data
usage. The shorter the interval, the higher the data usage. Valid range: 0000-FFFF.
Receiver Diagnostic Testing
[693] Integration Server IP
This section displays the IP address of the third party server. Do not program this section if a domain name is programmed in
setion [697].
[694] Integration Notification Port
This section is used to program the TCP Integration port for real time notification
[695] Integration Polling Port
This section is used to program the integration server port. Refer to third party device manual for more information
[697] Integration Server DNS
Enter the domain name (up to 32 ASCII characters) as provided by a third- party device. Refer to third party device manual for
more information.
[698] Integration outgoing port
This section is used to program the outgoing port for integration via UDP.
[699]Integration incoming port
This section is used to program incoming port for integration via TCP.
[901] Diagnostic Test Transmission
[1] Ethernet 1 (OFF).
[2] Ethernet 2 (OFF).
[3] - [8] Reserved (OFF).
18